OLIVEIRA, ELOANA P.R. de
; VICENTE, JOSE G.; OLIVEIRA, RENE R. de
; COUTO, ANTONIO A.
.
Fatigue behavior effect of shot peening associated to plasma nitriding surface treatment in F138 stainless steel.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 418-418.
Abstract:
Analysis of shot peening associated to plasma nitriding surface layers on austenitic stainless
steel are conduced to verify the influence of the surface treatment in fatigue behavior. Shot
peening can be used to increase fatigue resistance, due to the surface residual stress
induced. Additionally, shot peening can be used as a previous plasma nitriding treatment to
improve nitrogen atoms diffusion, increasing the layer hardness, thickness and fatigue
resistance [1]. Thus, the aim of the present work is to study the effect of previous shot
peening surface treatment in plasma nitrided F138 stainless steel fatigue properties.
Specimens treated with plasma nitriding and shot peening associated to plasma nitriding
were analyzed in high cycle fatigue tests. Previous shot peening treatment to plasma
nitriding promoted a failure in lower strength values than reference specimens, and its
similar to plasma nitride specimens. The result can be associated to roughness increase due
to shot peening and plasma nitriding treatments, which can influence fatigue behavior as
other surficial morphological characteristics of the formed layer [2]. Fracture surface were
analyzed by scanning electron microscopy (SEM) and ductile fracture surface was observed
in all conditions. In higher load conditions cracks and microcraks were formed on the sides
of the specimen.
OLIVEIRA, ELOANA P.R. de; VICENTE, JOSE G.; OLIVEIRA, RENE R. de; COUTO, ANTONIO A.
Fatigue behavior effect of shot peening associated to plasma nitriding surface treatment in F138 stainless steel.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 418-418.
Disponível em: http://repositorio.ipen.br/handle/123456789/34573. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GUARNIERI, GUILHERME de P.; NERY, JOSE G.; COSENTINO, IVANA C.
.
Converting waste materials into biomaterials: enriched calcium zeolites synthed from chicken eggshells for hemostatic applications.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 399-399.
Abstract:
Although there is a plethora of 245 different zeolites with different frameworks with unique
and unusual topologies of channels and cavities with large applications in the field of
industrial catalysis [1], few of them have found systematic biomedical applications,
especially for the purpose of hemorrhage control. Hemostasis is a complex biochemical
process in which the assembly of substrates, enzymes, protein cofactors and calcium ions on a
phospholipid surface accelerates the rate of coagulation. Several inorganic solid matrices
have been employed as topic hemostatic agents, and among them zeolites [2]. However, the
synthesis of enriched calcium zeolites for the purpose of hemorrhage control and using as
raw materials chicken eggshell biomass is an unexplored field of research. We report the
data of the synthesis of four calcium zeolites using CaCO3 derivated from chicken eggshell.
Thromboelastographic results using the pristine calcium enriched zeolites show that they
were able to promote a faster clot formation and a higher maximum clot strength than those
of the commercial topical hemostatic agent QuikClot.
GUARNIERI, GUILHERME de P.; NERY, JOSE G.; COSENTINO, IVANA C.
Converting waste materials into biomaterials: enriched calcium zeolites synthed from chicken eggshells for hemostatic applications.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 399-399.
Disponível em: http://repositorio.ipen.br/handle/123456789/34572. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SARTORI, MARIANA do N.
; CASTRO, DIONE P. de
; SILVA, LEONARDO G. de A. e
.
Reuse of textile waste with nano reinforcement for the development of materials incorporated with nanocomposites.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1933-1933.
Abstract:
The use of plastics in Brazil and the world has shown a growing demand due to their
qualities,
ease of obtaining, and low cost, and, consequently, produces an increase of these plastics in
solid
urban waste. The destination of these materials, especially in Brazil, is summarized in
sending to
landfills, incineration and, mechanical and chemical recycling. This study evaluates the
possibility
of using polyamide textile waste with elastane discarded by the textile industry, as
reinforcement for the development of a polymer-clay composite, on a nanometric scale, and
develop a recycling route for these materials. In that, the nanocomposite technology adds
value
to this material. This work used polyamides from textile waste of the industry. These
materials
were first processed in a compacting machine. Afterward the composites with 1, 2, and 3%
in
mass of Verde Clara clay/polyamide were prepared in a double screw extruder. The
composites
were characterized by techniques of X-ray diffraction (XRD), tensile, flexural, impact tests
and
thermogravimetric analysis (TGA). Results obtained were compared with the properties of
the
standard samples. As a conclusion of this study, it can be stated that the polyamide textile
scraps
with elastane can be reused forming nanocomposites with Verde Clara clay. Verde Clara
clay in
the proportion of 1% already confers gains in the properties of these nanocomposites.
SARTORI, MARIANA do N.; CASTRO, DIONE P. de; SILVA, LEONARDO G. de A. e.
Reuse of textile waste with nano reinforcement for the development of materials incorporated with nanocomposites.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1933-1933.
Disponível em: http://repositorio.ipen.br/handle/123456789/34571. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, CRYSTIAN W.C. da
; OTUBO, LARISSA
; SOUZA, KATIUSSE S. de
; CARBONARI, ARTUR W.
; CORREA, BRUNO S.
; FREITAS, RAFAEL S. de; PASCA, GABRIEL A.; COSTA, CLEIDILANE S..
Comparative local analysis of Ni/Ni3C nanoparticles synthed with oleylamine/oleic acid and oleylamine/palm kernel oil ligand pairs: structural and magnetic properties.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1805-1805.
Abstract:
In recent decades, Ni/Ni3C nanoparticles have been a topic of interest, especially for their
catalytic and magnetic properties, promising as electrocatalysis, for example [1]. These
systems are usually obtained by chemical methods, in the presence of ligands responsible
for controlling their structure and morphology [2]. In this work, we carried out a
comparative study of the hyperfine interactions occurring in Ni/Ni3C nanoparticles, synthed
by thermal decomposition in the presence of oleylamine/oleic acid and oleylamine/palm
kernel oil ligand pairs, at 513 K, for 3 hours. The local analysis was performed using
perturbed correlation spectroscopy (PAC) in the temperature range from 30K to 300K, using
the 111Cd probe, implanted in the samples by diffusion, during the synthesis. The
parameters of the hyperfine interactions were compared to the results obtained by XRD,
TEM and magnetization, indicating the obtainment of Ni/Ni3c nanoparticles of the core-shell
type, showing a higher Ni3C content, greater distribution and lower saturation
magnetization for nanoparticles synthed with palm kernel oil compared to those obtained
with oleic acid. In addition, the hyperfine parameters showed the existence of regions with a
quadrupole frequency of 24 MHz and a magnetic hyperfine field of 1T in both samples,
which may be indicative of carbon-deficient Ni3C regions, predicted in the literature [3].
SILVA, CRYSTIAN W.C. da; OTUBO, LARISSA; SOUZA, KATIUSSE S. de; CARBONARI, ARTUR W.; CORREA, BRUNO S.; FREITAS, RAFAEL S. de; PASCA, GABRIEL A.; COSTA, CLEIDILANE S.
Comparative local analysis of Ni/Ni3C nanoparticles synthed with oleylamine/oleic acid and oleylamine/palm kernel oil ligand pairs: structural and magnetic properties.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1805-1805.
Disponível em: http://repositorio.ipen.br/handle/123456789/34570. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
QUEIROZ, FERNANDA M.; RIBEIRO, GLEICY de L.X.; CASTRO, RENATO S. de; SANTOS, ROGERIO G. dos; BUGARIN, ALINE de F.S.
; TERADA, MAYSA.
Influence of the additive manufacturing parameters on the Ti6Al4V microstructure.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1374-1374.
Abstract:
The 3D printing on an industrial scale describe the one more advanced techniques. In the
manufacturing process technology the model is created by successively layering material
from a digital 3D model. The 3D manufacturing process allows obtaining complex geometry,
weight reduction, and customized components. A careful microstructure characterization of
the produced components is necessary, since the parameters influence in surface
roughness, microhardness and corrosion resistance. Samples of Ti6Al4V built with the same
laser speed, hatch distance and layer thickness but different laser power were analyzed. The
variation in laser power influenced the roughness and corrosion resistance of the samples.
QUEIROZ, FERNANDA M.; RIBEIRO, GLEICY de L.X.; CASTRO, RENATO S. de; SANTOS, ROGERIO G. dos; BUGARIN, ALINE de F.S.; TERADA, MAYSA.
Influence of the additive manufacturing parameters on the Ti6Al4V microstructure.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1374-1374.
Disponível em: http://repositorio.ipen.br/handle/123456789/34569. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BUGARIN, ALINE de F.S.
; RIBEIRO, GLEICY de L.X.; CASTRO, RENATO S. de; QUEIROZ, FERNANDA M.; SANTOS, ROGERIO G. dos; TERADA, MAYSA; COSTA, ISOLDA
.
Influence of texturing parameters on surface modification of UNS S32101 duplex steel.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1373-1373.
Abstract:
The application of laser texturing aims to modify the surface without changing its chemical
composition. These alterations can be evaluated through mechanical, physical or chemical
tests. Texturing can be applied to improve efficiency in industrial processes, such as the
flowability of materials, by applying laser texturing to the internal surfaces of components.
This work aims to evaluate the influence of texturing parameters in the flow process of
industrial batchers. UNS S32101 lean duplex stainless steel (LDSS) samples were used for
the tests. For laser texturing of the surfaces, laser of Yb was used, with a wavelength of
1064 nm (infrared), using the scanning speed of 140 mm/s and pulse duration of 150 ns.
Two sets of textured samples were produced: with a frequency of 50 kHz and 2 kHz. In both
frequencys, the power(%) was set at 100, 60 and 20. The effect of texturing was analyzed
through microstructural characterization with tests of contact angle, roughness and
scanning electron microscopy.
BUGARIN, ALINE de F.S.; RIBEIRO, GLEICY de L.X.; CASTRO, RENATO S. de; QUEIROZ, FERNANDA M.; SANTOS, ROGERIO G. dos; TERADA, MAYSA; COSTA, ISOLDA.
Influence of texturing parameters on surface modification of UNS S32101 duplex steel.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1373-1373.
Disponível em: http://repositorio.ipen.br/handle/123456789/34568. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BUGARIN, ALINE de F.S.
; VIVEIROS, BARBARA V.G. de
; TERADA, MAYSA; GUILHERME, LUIS H.; NEVES, MAURICIO D.M. das
; COSTA, ISOLDA
.
Syringe cell method to study the corrosion resistance of the UNS S32101 lean duplex stainless steel welded by the gas tungsten arc welding double fusion (GTAW-DF).
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1178-1178.
Abstract:
This work aims to investigate the corrosion performance of the UNS S32101 lean duplex
stainless steel (LDSS) welded by the gas tungsten arc welding double fusion (GTAW-DF). In
the study, six welded samples were manufactured with different welding parameters. A
Syringe cell was used to characterize the electrochemical behavior of the different welded
zones by potentiodynamic polarization tests in NaCl 3,5 % (w.t.) and in a solution of citric
acid with addiction of NaCl to simulate the food industry. The results showed that the
welding parameters tested significantly affected the corrosion resistance of the LDSS UNS
S32101. Besides, a correlation was stablished between microstructure and electrochemical
behavior of fusion line (FL), heat affected zone (HAZ) and fusion zone (FZ).
BUGARIN, ALINE de F.S.; VIVEIROS, BARBARA V.G. de; TERADA, MAYSA; GUILHERME, LUIS H.; NEVES, MAURICIO D.M. das; COSTA, ISOLDA.
Syringe cell method to study the corrosion resistance of the UNS S32101 lean duplex stainless steel welded by the gas tungsten arc welding double fusion (GTAW-DF).
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1178-1178.
Disponível em: http://repositorio.ipen.br/handle/123456789/34567. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BARROS, REGIS de M.C. de
; NEVES, MAURICIO
.
Study of residual stresses and fracture toughness in welded and repaired joints using A516 Gr70 steel.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1168-1168.
Abstract:
The properties of welded joints subjected to cyclic loading is an important subject in several
áreas[1]. In this scenario, aiming to study this subject, welded joints made of ASTM A 516 GR
70 steel plates, with a thickness of 30.5 mm, welded by the MAG – Metal Active Gas
process (20% CO2) with the use of a K-bevel were analyzed. to allow full penetration due to
the high thickness [2]. The joints were manufactured with seven welding passes on each
side of the chamfer. After welding, one set was subjected to a repair pass, for remelting the
surface of the bead using the TIG (Tungsten Inert Gas) process, while another set was
subjected to two repair passes. This study aimed to analyze aspects of welded and repaired
joints: dimensions (height and width) of the bead, behavior of the residual stress profile
measured by X-ray diffraction, Vickers microhardness profile and fatigue crack nucleation
with based on ASTM E466 and E606 standards. The results indicated that the greater
number of repair passes decreased the compressive residual stress values in the transverse
and longitudinal directions, from -350 MPa to 50 MPa. There was greater uniformity in
hardness Vickers values (value between 200 and 210 HV) with the use of cord repairs. It
was observed that the fracture toughness presented values of 1500 J/mm (without repair)
and 900 J/mm (one pass and two repair passes), lower than that found in the material
without welding (3500 J/mm). Therefore, as the repair passes were performed, the residual
stresses in the weld bead tended to positive values, the hardness tended to stabilize with
values of 200 HV due to the increase in the number of repair passes and the fracture
toughness decreased in the welded material when compared to the values of the non-welded
material. There was no significant difference in fracture toughness between repair passes.
BARROS, REGIS de M.C. de; NEVES, MAURICIO.
Study of residual stresses and fracture toughness in welded and repaired joints using A516 Gr70 steel.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1168-1168.
Disponível em: http://repositorio.ipen.br/handle/123456789/34566. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA FILHO, JORGE C.; SILVA, SUELANNY C. da; TAKIISHI, HIDETOSHI
; JANASI, SUZILENE R.
; MARTINEZ, L.G.
; REY, JOSE F.Q.; ESCOTE, MARCIA T..
Influence of reduced graphene oxide on the fabrication to neodymium-iron-boron magnets by mechanical milling.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1131-1131.
Abstract:
The aim of this work was to prepare sintered Nd-Fe-B permanent magnets, following the
traditional powder metallurgy route, using reduced graphene oxide (rGO) in the mechanical
milling process. Also, it was to study the effect of rGO addition on the magnetic properties
of the as-prepared materials. rGO acts as a lubricant and effective milling medium,
preventing agglomeration, welding of the particles, and oxidation of the material. The
structure and morphology of the composite powders were characterized by X-ray diffraction,
Raman spectroscopy, and transmission electron microscopy. The magnetic properties of
sintered magnets were characterized using a permeameter. The highest values of
remanence (Br) and intrinsic coercivity (iHc) values were obtained for the sintered magnet
using 0.02 wt% rGO addition, Br = 1.1 T, and iHc = 764.0 kAm-1.
SILVA FILHO, JORGE C.; SILVA, SUELANNY C. da; TAKIISHI, HIDETOSHI; JANASI, SUZILENE R.; MARTINEZ, L.G.; REY, JOSE F.Q.; ESCOTE, MARCIA T.
Influence of reduced graphene oxide on the fabrication to neodymium-iron-boron magnets by mechanical milling.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1131-1131.
Disponível em: http://repositorio.ipen.br/handle/123456789/34565. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CONCI, MAYCOLN D.; OLIVEIRA, RENE R.
; CENTENO, DANY M.A.; GOLDENSTEIN, HELIO; FARINA, PAULA F. da S..
Evolution of residual stress on AISI D2 tool steel short time tempering.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1117-1117.
Abstract:
Some parameters are used in an attempt to estimate a relationship between time and
tempering heat treatment temperature of steels, among which the Hollomon-Jaffe
parameter stands out [1]. This work aimed to study the evolution of residual stresses in
short-time tempering treatment of AISI D2 tool steel, compared to conventional heat
treatment of tempering [2]. The samples were treated in dilatometry for a better control of
the thermal processing variables. Microstructural images were generated using optical and
scanning electron microscopy, including mapping using EDS. Vickers microhardness
measurements were performed. And the measurements of variations in residual stresses in
each of the treatment stages and at the end of the treatment cycles were performed by
analyzing the X-ray diffraction data using the Sen2Ψ technique [3]. The cycles composed of
tempering in short times carried out at 500 ºC or 600 ºC, for 10 seconds or 1 minute,
exhibited residual stress states similar to the conventional cycle, with a tendency towards
neutrality of the residual stress state and high hardness values. The final residual stresses
acquired by the AISI D2 tool steel in the thermal cycles studied, more specifically in the
tempering, can be attributed to the precipitation of tempering carbides, which when carried
out up to 600 ºC, occurs coherently, or at least partially coherently, to the matrix, producing
the neutrality of residual stresses, but when tempering is carried out at 700 ºC, it leads to
incoherent precipitation of carbides and matrix recrystallization, leading to an increase in
compressive residual stresses and a reduction in the hardness of the material, regardless of
the heat treatment time of tempering.
CONCI, MAYCOLN D.; OLIVEIRA, RENE R.; CENTENO, DANY M.A.; GOLDENSTEIN, HELIO; FARINA, PAULA F. da S.
Evolution of residual stress on AISI D2 tool steel short time tempering.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1117-1117.
Disponível em: http://repositorio.ipen.br/handle/123456789/34564. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TURCARELLI, TIAGO
; CAMARGO, FABIO de; NEVES, MAURICIO M. das
.
Effect of EBW process welding parameters on AISI 304L stainless steel bead geometry.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1096-1096.
Abstract:
One important field in the welding researches is the study of the relationship between the
welding bead geometry and welding machine parameters. In electron beam welding (EBW)
process, the fine controlled parameters enable a detail understand of the weld profile. EBW
provides a concentrated beam of energy which can result in a high ratio of weld depth to
bead width, which can be called a keyhole. EBW is widely study because of its importance in
nuclear and aerospace application, mainly as a result of keyhole bead geometry. The
relationship between the welding bead geometry, width root and depth with welding
machine parameters is presented in this work by setting beam current and beam deflection
frequency. All experiments were carried out on samples of AISI 304L alloy with a thickness
(t) = 10 mm, accelerating voltage U = 60 KV, beam current range I = 34 – 43 mA, welding
speed v = 480 mm/min, vacuum p < 10-4 mbar, beam deflection width d = 1.2 mm and
beam deflection frequency f = 400 / 600 Hz. The weld joint geometry has changed by
varying of beam current and beam deflection frequency. The weld penetration was
increased by increment of beam current and deflection frequency. Set the frequency at f =
600 Hz and changing the beam current from 34 mA to 39 mA, it was observed that
penetration rise from 7.38 mm to 8.46 mm, respectively. On the other hand, when was
modified deflection frequency from 400 Hz to 600 Hz, the average welding penetration
surged 6.3%. Moreover, with deflection frequency kept in f = 400 Hz, a beam current
increment from I = 37 mA to I = 43 mA led to grow the welding penetration from 7.56 to
8.63, respectively. The results of weld width root showed no variation due to an increase of
beam current, however applying a change of electron beam deflection frequency from 600
Hz to 400 Hz was verified a slight increase in it. In conclusion, the welding bead geometry is
directly affected by varying of current beam and deflection frequency parameters.
TURCARELLI, TIAGO; CAMARGO, FABIO de; NEVES, MAURICIO M. das.
Effect of EBW process welding parameters on AISI 304L stainless steel bead geometry.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1096-1096.
Disponível em: http://repositorio.ipen.br/handle/123456789/34563. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, ALEXIA O.; NUNES, MATHEUS C. dos S.; YOSHIMURA, ELISABETH M.; RODRIGUES JUNIOR, ORLANDO
; TRINDADE, NEILO M..
Thermoluminescence, fluorescence and electron paramagnetic resonance of natural alexandrite.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1016-1016.
Abstract:
Recent studies have proposed the investigation of alexandrite mineral (BeAl2O4:Cr3+) as a
potential luminescent dosimeter. Despite this, in-depth studies of defects and luminescent
centers in alexandrite were not investigated. It is proposed to characterize the
thermoluminescence (TL) emission spectra, fluorescence (FL) and electron paramagnetic
resonance (EPR) of alexandrite. TL dosimeters, when stimulated by thermal energy, emit
light proportional to the dose of ionizing radiation previously absorbed. The emitted
wavelength can be measured through thermoluminescence emission spectra. On the other
hand, EPR and FL provides additional information about mineral structure, enabling the study
of the effects of ionizing radiation on the sample. For TL, the samples were irradiated with Xrays
and measured by Lumi22 homemade system. EPR measurements were carried out using
a Bruker EMXplus spectrometer operating in the X-band at room temperature, 2 mW
microwave power, 100 kHz modulation frequency and 0.25 mT modulation amplitude. The
FL spectra were measured using the Duetta spectrofluorometer, with a 75 W xenon arc lamp
included. The data was collected by scanning excitation wavelengths in 360-480 nm and
recording emission in the wavelength range of 670-740 nm. Preliminary results indicate that
the TL emission spectra presented two peaks, at ~80°C and ~175°C, with emission centered
between 600 nm – 700 nm, related to Fe3+ and Cr3+, also detected by EPR. The FL spectra
showed two signals: an emission centered at 680 nm (Cr3+ in inversion center), and at 700
nm (Cr3+ in mirror symmetry). The results of all techniques used in this work suggest that
emissions are correlated to Cr3+ and Fe3+ ions.
SILVA, ALEXIA O.; NUNES, MATHEUS C. dos S.; YOSHIMURA, ELISABETH M.; RODRIGUES JUNIOR, ORLANDO; TRINDADE, NEILO M.
Thermoluminescence, fluorescence and electron paramagnetic resonance of natural alexandrite.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1016-1016.
Disponível em: http://repositorio.ipen.br/handle/123456789/34562. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, BARBARA P.G.
; OTUBO, LARISSA
.
The influence of PVP molecular weight in the synthesis of silver nanowires using a salt-assisted polyol method.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 877-877.
Abstract:
In the last decades, the demand for new materials to be used in electronic devices has
increased. Among the materials that can be used in transparent conductive films (TCFs), are
the silver nanowires (AgNWs). This class of material, when supported in glass or PET, e.g.,
has good conductivity, thermal and mechanical properties and also high transparency. In
this work, the AgNWs were synthesized using the polyol method assisted by a salt and the
influence of molecular weight of the capping agent polyvinylpyrrolidone (PVP) in the
morphology and structure of Ag crystals was investigated. Different molecular weight of
PVP (40 K, 120 K, 360 K and 1300 K MW) was used in the synthesis. The surface
morphology of the products was observed by scanning electron microscopy and atomic force
microscopy. The phase composition and structure were analyzed by X-ray diffraction (XRD)
and the XRD patterns diffraction peaks correspond with the face-centered-cubic (fcc)
crystalline phase of silver. Transmission electron microscopy was used to analyze the crystal
structure, and UV-visible spectroscopy was used to follow the formation of Ag structures.
The results indicate that PVP and its chain length have an important role in the formation of
silver nanocrystals due to the adsorption and steric effects [1] and as high is the molecular
weight of PVP, longer and thinner are the AgNWs as observed by other authors [2].
Different morphologies were obtained when changing the size of PVP chain. For smaller
MW of PVP, particles and short wires were formed. Increasing the MW, nanorods and
pyramidal particles were formed, and finally, forming nanowires when using the highest
MW PVP of the experiments.Improving the aspect ratio of silver nanowires is important to
construct TCFs, since the conductivity and transparency properties are improved when they
are thinner and longer.
SILVA, BARBARA P.G.; OTUBO, LARISSA.
The influence of PVP molecular weight in the synthesis of silver nanowires using a salt-assisted polyol method.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 877-877.
Disponível em: http://repositorio.ipen.br/handle/123456789/34561. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BENTO, RODRIGO T.
; ABE, IGOR Y.; CORREA, OLANDIR V.
; PILLIS, MARINA F.
.
Raman spectroscopy applied on the structural characterization of TiO2/expanded graphite films.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 707-707.
Abstract:
Photocatalytic heterojunctions obtained from the use of titanium dioxide (TiO2) and carbon based
materials are a promising way for the efficient water treatment [1]. The structural
properties of the composite photocatalysts are an important characteristic that can
influence their photocatalytic behavior [2]. Here, TiO2/expanded graphite (TiO2-EG) films
were synthetized by sol-gel and deposited on borosilicate glass substrates by airbrush spray
coating method at room temperature. Then, the hybrid films were heat treated at 350, 450
and 550 °C. Raman spectroscopy technique was applied to evaluate the effect of carbon
amount and temperature on the structural properties of the films. The films heat treated at
350 °C exhibited a characteristic profile of amorphous material. Raman spectra of
composite films heat treated at 450 and 550 °C showed well-defined peaks that can be
attributed to anatase-TiO2phase. No peaks related to the rutile or other phases were
observed. The investigation revealed that the G and 2D bands present a slight shift, as well
as asymmetry, as the carbon content and heat treatment temperature increase – behavior
that may be associated with the formation of the semiconductor-C heterojunction. Peaks
deconvolution process demonstrated the presence of a second signal not found in the pure
films. This effect may indicate a reduction of sp2 domains after the formation of
semiconductor-C heterojunction, mainly due to the removal of oxygenated groups during
heat treatment, and consequent Ti-C / Ti-O-C bonds formation [3]. The results suggested
that the carbon amount and the temperature of heat treatment have great influence on the
TiO2 -EG structural properties, which may contribute to the improvement of the
photocatalytic activity of the composite films under visible light.
BENTO, RODRIGO T.; ABE, IGOR Y.; CORREA, OLANDIR V.; PILLIS, MARINA F.
Raman spectroscopy applied on the structural characterization of TiO2/expanded graphite films.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 707-707.
Disponível em: http://repositorio.ipen.br/handle/123456789/34560. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ROSERO, WILMMER A.A.
; BARBEZAN, ANGELICA B.
; RIGO, MARIA E.Z.
; RODRIGUES, PRISCILA S.
; TEODORO, LARA E.H.
; TALACIMON, CRISTHIAN F.
; ZEITUNI, CARLOS A.
; ROSTELATO, MARIA E.C.M.
.
Development of radioactive nanoparticles functionalized with gum arabic to be used in nanobrachytherapy.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 553-553.
Abstract:
The development of new materials emerges as an alternative to the treatment of cancer,
from the combination of nanotechnology and brachytherapy a new area of research was
born, Nanobrachytherapy, which through the properties of nanometric materials can
achieve better results in the fight against cancer. The objective of this work is classified as
radiotherapy, which consists of the use of ionizing radiation to destroy or inhibit the growth
of abnormal cells that form a tumor. [1] The ability to integrate NPsAu into biological
systems is due to the nanometric dimensions of NPsAu probes which facilitate their
incorporation into biological systems, as well as their bioconjugation and non-cytotoxic
potential. [2] Taking into account the previous objective, gold was selected as the base
element for obtaining nanometric systems, which due to its chemical richness and especially
due to the intrinsic properties of one of its radioisotopes, which would allow us in theory to
meet the stated objective. . Initially, it was based on the knowledge of the literature, and
non-radioactive nanometric systems were obtained, and after a series of stability,
characterization and application tests, the radioactive nanometric systems were obtained.
Working with radioactive systems posed a great challenge, and up to now it presents us
with situations to solve, but we have managed to create a methodology for obtaining,
characterizing and applying radioactive gold nanoparticles, and also obtaining positive
results from their application.
ROSERO, WILMMER A.A.; BARBEZAN, ANGELICA B.; RIGO, MARIA E.Z.; RODRIGUES, PRISCILA S.; TEODORO, LARA E.H.; TALACIMON, CRISTHIAN F.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.
Development of radioactive nanoparticles functionalized with gum arabic to be used in nanobrachytherapy.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 553-553.
Disponível em: http://repositorio.ipen.br/handle/123456789/34559. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TEODORO, LARA E.H.
; TALACIMON, CRISTHIAN F.
; RIGO, MARIA E.Z.
; RODRIGUES, PRISCILA S.
; NOGUEIRA, THUANY C.
; ROSERO, WILMMER A.A.
; VIEIRA, JOSE M.
; ZEITUNI, CARLOS A.
; ROSTELATO, MARIA E.C.M.
.
Possible molds for a new brachytherapy source for spinal and intracranial cancer.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 461-461.
Abstract:
Central Nervous System (CNS) cancer is the 18th most incident cancer in the world,
according to the World Health Organization (WHO), and in 2020, in Brazil, it represented
2.5% of all new cancer deaths [1]. Brachytherapy is a type of radiotherapy that positions the
radioactive source close to (or in contact with) the tumor. Thus, the targeted region receives
most of the dose, protecting the healthy tissues adjacent to the tumor. A promising
radioactive source for use in brachytherapy for the treatment of CNS cancer is
phosphorus-32 in a polymeric substrate. This source has been prominent as a minimally
invasive treatment for craniopharyngiomas and in the treatment of metastatic bone diseases
in general [2]. To produce such a source, it is necessary to search for possible molds that
can conform the polymeric material into the desired format. Several tests were carried out
to determine the best mold for the radioactive source manufacture. Different materials were
tested to observe if the mold material would react with the source's components, silicone
rubber mixed with orthophosphoric acid. In order to be considered a possible mold, the
mixture should cure; if the cure did not concretize, the mold would be descarted. It was
concluded that polystyrene (PS) obtained the best result, due to the ease of unmold after the
resin curing process.
TEODORO, LARA E.H.; TALACIMON, CRISTHIAN F.; RIGO, MARIA E.Z.; RODRIGUES, PRISCILA S.; NOGUEIRA, THUANY C.; ROSERO, WILMMER A.A.; VIEIRA, JOSE M.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.
Possible molds for a new brachytherapy source for spinal and intracranial cancer.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 461-461.
Disponível em: http://repositorio.ipen.br/handle/123456789/34558. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CARVALHO, JOAO V.M.S.
; SILVA, ROGERIO M.V.; CALDAS, LINDA V.E.
.
Validation of a radiotherapy sector with an END-TO-END test in an anthropomorphic phantom for radiosurgery from a 3D printer.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 76.
CARVALHO, JOAO V.M.S.; SILVA, ROGERIO M.V.; CALDAS, LINDA V.E.
Validation of a radiotherapy sector with an END-TO-END test in an anthropomorphic phantom for radiosurgery from a 3D printer.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 76.
Disponível em: http://repositorio.ipen.br/handle/123456789/34557. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GARCIA, JOAO I.M.M.; GOMES, ANDERSON M.; ZAMBUZZI, WILLIAN F.; ICHIKAWA, RODRIGO U.
; SAEKI, MARGARIDA J..
Influence of temperature on obtaining apatites by sol- gel method.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 434-434.
Abstract:
Calcium phosphate-based ceramics (apatites) are synthetic materials that have a chemical
composition similar to bone tissue, which makes them interesting to use as biomaterials [1].
In this work, the apatite precursor sols at concentrations of 0.7 mol/L and 1.4 mol/L are
prepared by dissolving calcium nitrate and phosphorus pentoxide in ethanol. The sols are
kept at rest for 24 hours for hydrolysis (gelatinization) under room temperature and
humidity. After hydrolysis, the resulting gels are dried at 80°C to remove the organic
solvent and then calcined under different temperatures (from 500°C to 1200°C, with
increments of 100°C) for 8h [2]. The X-ray diffraction analysis of the samples by the Rietveld
method indicates that the samples are composed of monoclinic and hexagonal
hydroxyapatite (HAp), the former being predominant, and calcium β-triphosphate (TCP)[3] . For
the material started from the sol with a concentration of 0.7 mol/L, the hydroxyapatite
fraction increases from 28.8% to 66.5% when the calcination temperature increases from
500°C to 800°C. Above this temperature, the fraction of this phase decreases. With a
concentration of 1.4 mol/L, the hydroxyapatite fraction decreases from 88.2% to 19.5%
progressively with increasing temperature from 500°C to 1200°C. The micrographs revealed
the formation of particulate but porous materials that agglomerate without sintering
up to a temperature of 900°C, from where the formation of sintered and dense agglomerates
is observed. The results of the EDX analysis showed a Ca/P molar ratio of around 1.5 for
all materials. The cytotoxicity assay, using pre-osteoblast cells (MC3T3-E1, Subclone 4) by
non-direct contact of 24h, showed that cell viability and adhesion did not differ from those
of the control. A decrease in viability and adhesion was observed for samples prepared at
a concentration of 0.7 mol/L and calcined at temperatures above 900°C.
GARCIA, JOAO I.M.M.; GOMES, ANDERSON M.; ZAMBUZZI, WILLIAN F.; ICHIKAWA, RODRIGO U.; SAEKI, MARGARIDA J.
Influence of temperature on obtaining apatites by sol- gel method.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 434-434.
Disponível em: http://repositorio.ipen.br/handle/123456789/34556. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
LOURENCO, LARISSA R.; BORGES, ROGER; CARASTAN, DANILO J.; MATHOR, MONICA B.
; MARCHI, JULIANA.
Chitosan hydrogel containing bioactive glass aiming at 3D printing for tissue engineering.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 349-349.
Abstract:
3D printing is a rising processing technique in tissue engineering due to high reproducibility
and the possibility of complex or even patient-specific models. Chitosan is a promising
biomaterial for both 3D printing and tissue engineering, because of its biocompatibility,
rheological properties, biodegradability, and cost-effectiveness. Bioactive glasses can help the
regeneration of different biological tissues and act as reinforcement for chitosan matrix. In
this work, chitosan hydrogels were produced with different concentrations of 58S
bioactive glass (0.5 up to 5%wt). For the rheological characterization, frequency, and
recovery experiments were carried out. Printability and shape fidelity were evaluated during
the 3D printing process. Indirect cytotoxicity assay using Balb/c 3T3 cells was performed to
evaluate the biological properties of the scaffolds. The presence of the glass maintained the
viscosity properties and increased the recovery percentage. All materials formed filaments
and allowed printing with suitable form maintenance. Biological experiments showed high
cell viability for all 3D scaffolds, even though a reduction was observed for higher glass
concentrations. The results indicate that the studied materials are printable and potentially
recommended for tissue engineering applications.
LOURENCO, LARISSA R.; BORGES, ROGER; CARASTAN, DANILO J.; MATHOR, MONICA B.; MARCHI, JULIANA.
Chitosan hydrogel containing bioactive glass aiming at 3D printing for tissue engineering.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 349-349.
Disponível em: http://repositorio.ipen.br/handle/123456789/34555. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
QUEIROZ, CARLOS A. da S.
.
Preparation of lanthanum acetate from a mixed rare earths concentrate.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1153-1153.
Abstract:
A simple and economical chemical process to obtaining lanthanum acetate of high purity
was studied. The raw material in the form of mixed rare earths carbonate 24% La2O3 comes
from commercial Brazilian monazite. It is used the technique of strong cationic exchange
resin, proper to water treatment to the lanthanum''s fractionation and it is achieved a purity
of 99.9% La2O3 and yield greater than or equal 90%, with the elution of rare earths by
EDTA solution at pH 4.0. The complex of EDTA-La is transformed in La2O3 , subsequently
the lanthanum oxide is dissolved in acetic acid to obtain the cerium acetate. The solid salt
then is characterized via chemical analysis, thermal analysis, X ray diffraction, infrared
spectroscopy and mass spectrometry to certify the lanthanum acetate purity. The analytical
data collected allowed to conclude that the stechiometric formula for the compound is La
(CH3COO)3.1.5 H2O.
QUEIROZ, CARLOS A. da S.
Preparation of lanthanum acetate from a mixed rare earths concentrate.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1153-1153.
Disponível em: http://repositorio.ipen.br/handle/123456789/34554. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
LOBO, RAQUEL de M.
; CASTAGNET, MARIANO
; MIRANDA, CARLOS A. de J.
; FALOPPA, ALTAIR A.
; LIMA, JOSE R. de
; MATTAR NETO, MIGUEL
; PEREIRA, LETICIA dos S.
; ANDRADE, ARNALDO H.P. de
.
Correlations of mechanical properties by SPT (Small Punch Test) and conventional tensile test for Al 6061 – T6.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1084-1084.
Abstract:
The Small Punch Test (SPT) was development by nuclear industries to analyses mechanical
properties of irradiated materials principally by small volume of the samples. This technique
intend to evaluate the materials behavior during the time life of nuclear reactors, where
yours properties changed by irradiation intensity and exposition time. It is considered an
almost ¨non-destructive” method [2] due to small sample volume and its applications are
spreading for use in situations where conventional methods do not apply. SPT consists of
pressing a sphere, with a diameter equal to 2.5 mm, in a miniaturized sample of circular
geometry (diameter d = 8 mm and thickness about 0.5 mm)[1], which has fixed edges,
tested in conventional mechanical testing machines with the aid of a device developed for
their achievement. In this work, mechanical properties of aluminum (Al 6061-T6) were
abstained by two different methods: conventional tensile test and the small punch test
(SPT). The SPT results depends on graph interpretations and discussions take place at now.
Correlations of results guide us in choosing the most appropriated method for interpreting
the force x displacement graph from SPT.
LOBO, RAQUEL de M.; CASTAGNET, MARIANO; MIRANDA, CARLOS A. de J.; FALOPPA, ALTAIR A.; LIMA, JOSE R. de; MATTAR NETO, MIGUEL; PEREIRA, LETICIA dos S.; ANDRADE, ARNALDO H.P. de.
Correlations of mechanical properties by SPT (Small Punch Test) and conventional tensile test for Al 6061 – T6.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1084-1084.
Disponível em: http://repositorio.ipen.br/handle/123456789/34553. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
NOGUEIRA, THUANY
; TALACIMON, CRISTHIAN
; TEODORO, LARA
; RIGO, MARIA
; RODRIGUES, PRISCILA
; ANGELOCCI, LUCAS
; NOVAES, HAMONA
; ZEITUNI, CARLOS
; ROSTELATO, MARIA
.
Thermoluminescent dosimetry planning through MNCP.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 190.
NOGUEIRA, THUANY; TALACIMON, CRISTHIAN; TEODORO, LARA; RIGO, MARIA; RODRIGUES, PRISCILA; ANGELOCCI, LUCAS; NOVAES, HAMONA; ZEITUNI, CARLOS; ROSTELATO, MARIA.
Thermoluminescent dosimetry planning through MNCP.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 190.
Disponível em: http://repositorio.ipen.br/handle/123456789/34552. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PEREIRA, MARIA da C.C.
; MADI FILHO, TUFIC
; BERRETTA, JOSE R.
; ALVES, JOAO P. da S.
.
Response of CsI:Pb scintillator crystal to neutron radiation.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1014-1014.
Abstract:
The helium-3 world crisis requires a development of new methods of neutron detection to
replace commonly used 3He proportional counters. In the past decades, great effort was
made to developed efficient and fast scintillators to detect radiation.[1] These detectors
should, then, be carefully characterized both experimentally and by means of advanced
simulation code. Ideally, the detector should have the capability to separate neutron and
gamma induced events either by amplitude or through pulse shape differences. As neutron
sources also generate gamma radiation, which can interfere with the measurement, it is
necessary that the detector be able to discriminate the presence of such radiation.
Considerable progress has been achieved to develop new inorganic scintillators, in
particular increasing the light output and decreasing the decay time by optimized doping.
Crystals may be found to suit neutron detection. In this report, we will present the results of
the study of lead doped cesium iodide crystals (CsI:Pb) grown in our laboratory, using the
vertical Bridgman technique. The concentration of the lead doping element (Pb) was studied
in the range 5x10-4M to 10-2M. The crystals grown were subjected to annealing (heat
treatment). In this procedure, vacuum of 10-6 mbar and continuous temperature of 350°C,
for 24 hours, were employed. In response to neutron radiation, an AmBe source with energy
range of 1 MeV to 12 MeV was used. The activity of the AmBe source was 1Ci Am. The
fluency was 2.6 x 106 neutrons/second. The operating voltage of the photomultiplier tube was
1300 V; the accumulation time in the counting process was 600 s and 1800 s. The
scintillator crystals used were cut with dimensions of 20 mm diameter and 10 mm height.
The Monte Carlo method was used to determine the neutron flux arriving in the detector
and the calculated values were obtained by means of MCNP code.
PEREIRA, MARIA da C.C.; MADI FILHO, TUFIC; BERRETTA, JOSE R.; ALVES, JOAO P. da S.
Response of CsI:Pb scintillator crystal to neutron radiation.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 1014-1014.
Disponível em: http://repositorio.ipen.br/handle/123456789/34551. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, RAPHAEL A.M.P. de; TRINDADE, FABIANE J.; FLORIO, DANIEL Z. de; FONSECA, FABIO C.
; ESPOSITO, VINCENZO; FERLAUTO, ANDRE S..
Effects of La content in ceria-lanthana thin films prepared by pulsed laser deposition.
In: BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 810-810.
Abstract:
Solid oxide electrochemical reactors are a promising alternative for challenging chemical
reactions, such as oxidative coupling of methane (OCM)[1], which convert methane to
C2+products. Cerium oxide is a commonly studied oxide membrane material for its high ionic
conductivity in the temperature range ideal for conversion reactions (600-900°C),
particularly when doped with rare earth cations like Gd, Sm, or La. Recent studies have
shown La2Ce2O7as a promising OCM catalyst[2]. This study investigates the structural
properties of LaxCe(1-x)O2(1-x/2)thin films, prepared using pulsed laser deposition, with varying
stoichiometry. XRD results indicate textured film growth with preferential [100] orientation
of cubic crystalline fluorite for low La content (x≤0.5), while x>0.5 had a random
orientation. La doping expanded the fluorite structure, increasing lattice parameters from
5.42 Å for x=0 to 5.69 Å for x=0.7. UV-Raman spectroscopy showed that La content x=10
caused a more pronounced balance between Ce4+and Ce3+than pure ceria samples.
Impedance revealed a direct relationship between La content and resistance, indicating lower
resistance with lower La content. These findings could lead to using Ce-La oxides thin films as
catalysts for OCM in electrochemical reactors based on ceria.
OLIVEIRA, RAPHAEL A.M.P. de; TRINDADE, FABIANE J.; FLORIO, DANIEL Z. de; FONSECA, FABIO C.; ESPOSITO, VINCENZO; FERLAUTO, ANDRE S.
Effects of La content in ceria-lanthana thin films prepared by pulsed laser deposition.
In:
BRAZIL MRS MEETING, 21st,
October 1-5, 2023,
Maceió, AL.
Abstract...
São Carlos, SP: Aptor Software,
2023.
p. 810-810.
Disponível em: http://repositorio.ipen.br/handle/123456789/34550. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ANTONIO, PATRICIA L.
; SILVEIRA, IURY S.
; CALDAS, LINDA V.E.
.
Thermoluminescence and phototransferred thermoluminescence of radiation dosimeters:: analysis of the effect of UV light for transfer of charges from deep traps.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 123.
ANTONIO, PATRICIA L.; SILVEIRA, IURY S.; CALDAS, LINDA V.E.
Thermoluminescence and phototransferred thermoluminescence of radiation dosimeters:: analysis of the effect of UV light for transfer of charges from deep traps.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 123.
Disponível em: http://repositorio.ipen.br/handle/123456789/34549. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
DIAS, F.S.
; GIOVANNI, D.N.S.
; POTIENS JUNIOR, A.J.
; RODRIGUES JUNIOR, O.
; POTIENS, M.P.A.
; ZAMBONI, C.B.
.
Study on the radiation exposure of Portable X-ray Fluorescence.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 107.
DIAS, F.S.; GIOVANNI, D.N.S.; POTIENS JUNIOR, A.J.; RODRIGUES JUNIOR, O.; POTIENS, M.P.A.; ZAMBONI, C.B.
Study on the radiation exposure of Portable X-ray Fluorescence.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 107.
Disponível em: http://repositorio.ipen.br/handle/123456789/34548. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SA, MARCELO C. de
; CALVO, WILSON P.
; SOMESSARI, SAMIR L.
.
Regulatory requirements and economic feasibility for developing a mobile SPECT/CT unit with radiopharmacy facilities.
In: INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 168-168.
Abstract:
Brazil has been facing great challenges related to the public health care system, not being able to
manage the high national demand for diagnostic imaging tests, therefore avoiding the possibility
of an early diagnosis for oncological and cardiovascular diseases. An important medical specialty
for providing an early and accurate diagnosis is Nuclear Medicine. Early diagnosis is crucial for
health professionals to make decisions that enable more effective treatments and improve the
chances of cure.
Due to the irreversible damages caused to patient’s health resulting of delay in diagnosis, this
research project carried out at Nuclear and Energy Research Institute (IPEN/CNEN), together
private companies and associated institutions, focus on regulatory requirements and economic
feasibility for developing a mobile unit with hybrid Single Photon Emission Computed
Tomography/Computed Tomography (SPECT/CT) equipment and radiopharmaceuticals facilities
for radiolabeling reagents kits with technetium-99m.
A mobile SPECT/CT unit with adequate radiopharmacy facilities will be an excellent innovative
solution to support Brazilian public hospitals to address the demand for diagnostic imaging tests.
This mobile unit could provide health care in isolated areas or even big cities where there are
shortage of health resources and high mortality rate for cancer and heart disease.
SA, MARCELO C. de; CALVO, WILSON P.; SOMESSARI, SAMIR L.
Regulatory requirements and economic feasibility for developing a mobile SPECT/CT unit with radiopharmacy facilities.
In:
INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 168-168.
Disponível em: http://repositorio.ipen.br/handle/123456789/34547. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SANTOS, KATIA C.
; BERNARDES, EMERSON S.
; CALVO, WILSON P.
.
Production and application of 177Lu-PSMA and 225Ac-PSMA in the sustainable innovation model through Balanced Scorecard (BSC).
In: INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 173-173.
Abstract:
177Lu-PSMA and 225Ac-PSMA appear in the theranostic concept, with astonishing results in
prostate cancer patients, who did not respond to conventional therapies. In Europe, these
treatments are used successfully. However, in Brazil, 30% of patients do not respond well to new
radiopharmaceuticals, requiring broader studies.
The "Multicenter program using PSMA radioligands for diagnosis and therapy of patients with
prostate cancer", in which this research project is inserted, in partnership among the Nuclear and
Energy Research Institute (IPEN-CNEN), a private company and associated institutions, aims to
expand the therapeutic alternatives for patients with cancer unresponsive to the treatments
available in the public health network in the State of São Paulo.
IPEN-CNEN will produce the radiopharmaceuticals that will be distributed to Public Hospitals
responsible for the selection, treatment and follow-up of patients with metastatic castrationresistant
prostate cancer (mCPRC), and for the genetic and molecular characterization of patients
unresponsive to treatment.
The present research will study the technical and economic feasibility in the production and
application of these radiopharmaceuticals, with clinical studies in patients with mCPRC, applying
the Balanced Scorecard (BSC) management tool, measuring its performance by indicators aiming
at a strategic and efficient management, with the possibility of theirs marketing.
SANTOS, KATIA C.; BERNARDES, EMERSON S.; CALVO, WILSON P.
Production and application of 177Lu-PSMA and 225Ac-PSMA in the sustainable innovation model through Balanced Scorecard (BSC).
In:
INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 173-173.
Disponível em: http://repositorio.ipen.br/handle/123456789/34546. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ROSTELATO, MARIA E.C.M.
; FEHER, ANSELMO
; ZEITUNI, CARLOS A.
; ROSERO, WILMMER A.A.
; SOUZA, CARLA D. de
; MOURA, JOÃO A.
.
Nationalization of brachytherapy radioactive sources in Brazil and the importance of IAEA cooperation.
In: INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 23-23.
Abstract:
Brazil has a cancer incidence of about 625,000 cases a year. It is a public health problem, demanding
constant efforts to deliver for patients the most efficient treatment modalities, improving their life
expectancy and quality. Brachytherapy is a type of Radiotherapy where the radioactive source is placed
close to or inside the tumor. The main advantage of the technique is to deliver the maximum dose in the
target, saving healthy tissues. In Brazil, Our group had the objective of producing sources nationally,
diminishing treatment costs, enabling the treatment to more patients. Some of our projects are developed
in collaboration with the International Atomic Energy Agency-IAEA by technical cooperation projects. The
IAEA participation is very important to provide technological transfer through scientific visits, expert
missions, and contacts with more advanced centers. The financial support is also important, allowing us to
buy the necessary equipment to make these cancer treatment sources production feasible in Brazil. Our
team has received training through fellowships. We received some experts and organized several workshops
to propagate the Brachytherapy technique at national and Latin American level. For producing new sources,
five major areas must be considered: 1) source production: nuclear activation and/or radiochemical reaction;
2) welding; 3) quality control: leakage tests; 4) dosimetry and metrology; 5) operational procedures; 6)
validation studies. To perform all steps, a multidisciplinary team works together to overcome difficulties.
Our major projects are: Iridium-192 pellets: In Brazil there are 150 afterloading machines with pellets that
replacement every 4 months (about 450 Iridium-192 sources a year). Our new production line, with the
support of IAEA, is in progress, with the hot-cell being installed in a brand-new facility. Iridium-192 wires:
In production since 1997, also supported by IAEA. The wire is activated at IPEN’s IEA-R1 reactor for 30
hours with 5x1013 n/cm-2.s-1 neutron flux resulting in 7.1 GBq (192 mCi) maximum activity. Iridium-192
seed: New seed for ophthalmic cancer treatment. The core presented 90% activity homogeneity. We are
making the experimental dosimetry and Monte Carlo simulation. Iodine-125 seeds: Largely used in low
dose brachytherapy. I-125 binding yield achieved with our new reaction was 90%; Laser welding presented
70% efficiency. Approved in all leakage tests. Our Iodine-125 seeds laboratory production is 90% ready.
Other ongoing projects: polymeric Phosphorus-32 source for spinal cancer treatment, Gold-198
nanoparticles for prostate, breast, and liver cancer treatment, Iodine-125 seed as markers for non-palpable
cancers, and dosimetry calculations for all new sources. All the projects are advancing, despite national
funding difficulties. Withing those, several mSc, Phd, and Post-doc are getting their degrees. We will
continue to develop new products hoping to help the Brazilian population fight against cancer. The support
of IAEA has proven to be of the utmost importance for these projects not only in direct funding, but in
providing knowledge to our team, the possibility to share information with the scientific community, and
to form the next generation of scientists.
ROSTELATO, MARIA E.C.M.; FEHER, ANSELMO; ZEITUNI, CARLOS A.; ROSERO, WILMMER A.A.; SOUZA, CARLA D. de; MOURA, JOÃO A.
Nationalization of brachytherapy radioactive sources in Brazil and the importance of IAEA cooperation.
In:
INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 23-23.
Disponível em: http://repositorio.ipen.br/handle/123456789/34545. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SAVI, M.; VILLANI, D.
; ANDRADE, M.A.B.; SOARES, F.A.P.; RODRIGUES JUNIOR, O.
; CAMPOS, L.L.
; POTIENS, M.P.A.
.
Step-by-step of 3D printing a head-and-neck phantom: proposal of a methodology using fused filament fabrication (FFF) technology.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 43.
SAVI, M.; VILLANI, D.; ANDRADE, M.A.B.; SOARES, F.A.P.; RODRIGUES JUNIOR, O.; CAMPOS, L.L.; POTIENS, M.P.A.
Step-by-step of 3D printing a head-and-neck phantom: proposal of a methodology using fused filament fabrication (FFF) technology.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 43.
Disponível em: http://repositorio.ipen.br/handle/123456789/34544. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ROSERO, WILMMER A.A.
; BARBEZAN, ANGELICA B.
; ROSTELATO, MARIA E.C.M.
; SOUZA, CARLA D. de
; NOGUEIRA, BEATRIZ R.
; ZEITUNI, CARLOS A.
.
Synthesis, activation and application testing of gold nanoparticles for nanobrachytherapy.
In: INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 24-24.
Abstract:
For more than 50 years, the Energy and Nuclear Research Institute IPEN, has been offering
solutions to Brazil through nuclear technology. Thus, one of the main areas where IPEN has
contributed assertively is medicine. Reaching the level of 32 radiopharmaceuticals and radioactive
sources intended both for therapy and for the diagnosis of several pathologies, including cancer,
which are obtained with the help of the two nuclear reactors and two cyclotrons present in the
institution. The Institute has a team for the development, production and distribution of radioactive
sources for brachytherapy, such as 192 Ir wires and 125 I seeds. Brachytherapy is a cancer
treatment technique where the radioactive source is placed close to or in contact with the lesion.
The great advantage of the technique is to save healthy tissues. Currently, we are working on
obtaining nanometric materials that can be applied in the emerging nano brachytherapy, because
of its properties and characteristics at the nanometric level, gold has been the subject of studies
and tests. Elemental Au gold can be activated 198 Au inside a nuclear reactor, and has β- decay
and a half-life of 2.7 days, which makes it ideal for short-term irradiations. In addition, gold in the
form of nanoparticles has a completely different chemistry, with gold nanoparticles (AuNPs) being
easily functionalized by a large part of molecular and polymeric binders, which may present
favorable characteristics for the studies, and together with AuNPs they are able to work
synergistically to achieve greater efficiencies. Currently, AuNPs have been successfully
functionalized with gum arabic (GA), a coating widely used in the cosmetic and food industry,
which is low cost and along with nanoparticles has shown biocompatibility with different cell
groups and has been shown to be very stable over time. The project includes studies regarding the
synthesis of nanoparticles, coating, cytotoxicity of AuNPs in vitro "cold" (non-radioactive) and
the development of activation protocols in the nuclear reactor. In the next phase, after activation,
in the reactor, "hot" tests will be performed in vitro and in vivo.
ROSERO, WILMMER A.A.; BARBEZAN, ANGELICA B.; ROSTELATO, MARIA E.C.M.; SOUZA, CARLA D. de; NOGUEIRA, BEATRIZ R.; ZEITUNI, CARLOS A.
Synthesis, activation and application testing of gold nanoparticles for nanobrachytherapy.
In:
INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 24-24.
Disponível em: http://repositorio.ipen.br/handle/123456789/34543. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FERREIRA, ARYEL
; FREITAS, LUCAS F. de
; GAMARRA, LIONEL F.; MARQUES, FABIO N.
; LUGAO, ADEMAR
.
Preclinical validation of freeze-dried kit of albumin nanoparticles synthesized by a radiolytic method.
In: INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 195-195.
Abstract:
Radiopharmaceutical kits containing human serum albumin nanoparticles (HSA-NP), which after
radiolabeling with Sodium Pertechnetate solution (99mTc) results in nanocolloids, are already
commercialized by international companies. These kits are used to characterize the lymphatic
system and, in particular, to detect sentinel lymph nodes in breast cancer and melanoma patients.
Albumin has also recently been extensively utilized to form nanoparticles for drug delivery in
cancer, i.e., Abraxane®, an FDA-approved nanomedicine consisting in paclitaxel encapsulated by
albumin nanoparticles (130 nm), for metastatic breast cancer treatment (2005), lung cancer (2012),
and metastatic pancreatic adenocarcinoma (2013). Well-established literature data, and
experimental data obtained by our CRP research, demonstrate that albumin nanoparticles
synthesized by gamma radiation have the potential to become a similar product to those available
on the market. As the particle size distribution is well defined and parameters such as qualitative
and quantitative composition are relevant and comparable to commercial ones. The albumin
nanoparticles produced by radiation synthesis were lyophilized in a radiopharmaceutical kit
containing HSA-NPs, Poloxamer 188, sodium phytate, tin chloride, glucose, and anhydrous
disodium hydrogen phosphate. The OECD Guidelines for the Testing of Chemicals were
performed to assure the safety of using the albumin nanoparticle freeze dried kits. The
development of studies included: Genotoxicity tests (OEDC 471: Bacterial Reverse Mutation Test,
OECD 474: Mammalian Erythrocyte Micronucleus Test), Carcinogenicity tests (OECD 453:
Combined Chronic Toxicity/Carcinogenicity Studies) and Acute Toxicity (OEDC 420). In
addition, biodistribution of 99mTc radiolabeled albumin nanoparticle was performed in healthy
mice. The results show that HSA-NP was not able to induce chromosomal breaks and/or
chromosomal gain or loss under experimental conditions, indicating no genotoxic effect.
Furthermore, it was considered non-mutagenic, as it did not induce mutations by shifting the
reading frame or substitution of base pairs in the genome of the strains used (TA97a, TA98,
TA100, TA102 and TA1535). The treated rats had weight gain and the blood counts showed no
abnormalities, in the same way normal biochemical parameters were found indicating the
nontoxicity of the product. Furthermore, the ex-vivo biodistribution study in normal mice showed
rapid blood clearance with high hepatobiliary and low renal excretion, which is in agreement with
literature studies and commercial products leaflets.
FERREIRA, ARYEL; FREITAS, LUCAS F. de; GAMARRA, LIONEL F.; MARQUES, FABIO N.; LUGAO, ADEMAR.
Preclinical validation of freeze-dried kit of albumin nanoparticles synthesized by a radiolytic method.
In:
INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 195-195.
Disponível em: http://repositorio.ipen.br/handle/123456789/34542. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FERREIRA, ARYEL
.
Heterodimer peptide based on RGD and NPY analog for breast tumor targeting.
In: INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 189-189.
Abstract:
Heterodimer peptides targeting more than one receptor target can be advantageous as tumors can
simultaneously express more than one receptor type. The design of heterodimer peptides can
significantly increase the avidity and specificity of the contrast agent due to simultaneous binding
to more than one type of receptor or at least one receptor independently, compared to their
corresponding monospecific counterparts. A heterodimer molecule consisting of cyclic RGD and
NPY analog motifs in a single probe is an attractive approach, as both receptors are overexpressed
simultaneously in breast cancer. We hypothesize that a peptide ligand recognizing both αvβ3
integrin and NPY receptors will be advantageous because of its dual-receptor-targeting ability,
which could enable the determination of disease location, monitoring of pathological and
molecular changes associated with payload delivery, as well as a comprehensive view of the
material behavior in vivo that can be utilized to guide therapeutic and diagnostic interventions.
The HYNIC-cRGDfk-NPY peptide was radiolabeled with 99mTc using tricine/EDDA as coligand.
The cellular-specific binding of [99mTc]HYNIC-cRGDfk-NPY was evaluated on different
cell lines as well as with a blocking experiment on MCF-7 and MDA-MB231 (human breast cancer
cells). The proof-of-concept of tumor-targeting was performed through ex vivo biodistribution in
normal mice, MCF-7 and MDA-MB231 tumor-bearing mice also in SPECT/CT images. By using
tricine/EDDA as a coligand, labeling yield was more than 97%. The in vitro cell uptake test showed
that this radiolabeled peptide had a good affinity to MDA-MB231 and MCF-7 cells. The in vivo
results showed a tumor/muscle ratio of 5.65 ± 0.94 for MCF-7 model, and 7.78 ± 3.20 for MDAMB231
Also, tumor uptake was reduced significantly from 9.30% to 4.41% (MCF-7) and from
4.93 % to 2.3% (MDA-MB231) in blocking study whereas 500-fold molar excess of cold peptide
was injected 30 min prior to the injection of related radioconjugated peptide suggesting the
potencial of heterobivalent radioligand [99mTc]-HYNIC-cRDGfk-NPY to target breast tumors
targeting.
FERREIRA, ARYEL.
Heterodimer peptide based on RGD and NPY analog for breast tumor targeting.
In:
INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 189-189.
Disponível em: http://repositorio.ipen.br/handle/123456789/34541. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TEODORO, LARA E.H.
; BURIN, ANA L.
; TALACIMON, CRISTHIAN F.
; MEDEIROS, ILCA M.M.A.
; RIGO, MARIA E.Z.
; TAVARES, PAULO V. dos S.
; RODRIGUES, PRISCILA S.
; NOGUEIRA, THUANY C.
; ROSERO, WILMMER A.A.
; RODRIGUES JUNIOR, ORLANDO
; VIEIRA, JOSE M.
; ZEITUNI, CARLOS A.
; ROSTELATO, MARIA E.C.M.
.
Using a Monte Carlo simulation to analyze the ideal activity for a phosphorus-32 polymeric brachytherapy source for paraspinal tumors.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 171.
TEODORO, LARA E.H.; BURIN, ANA L.; TALACIMON, CRISTHIAN F.; MEDEIROS, ILCA M.M.A.; RIGO, MARIA E.Z.; TAVARES, PAULO V. dos S.; RODRIGUES, PRISCILA S.; NOGUEIRA, THUANY C.; ROSERO, WILMMER A.A.; RODRIGUES JUNIOR, ORLANDO; VIEIRA, JOSE M.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.
Using a Monte Carlo simulation to analyze the ideal activity for a phosphorus-32 polymeric brachytherapy source for paraspinal tumors.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 171.
Disponível em: http://repositorio.ipen.br/handle/123456789/34540. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FEHER, ANSELMO
; BAPTISTA, TATYANA S.
; ZEITUNI, CARLOS A.
; ROSTELATO, MARIA E.C.M.
; MOURA, JOÃO A.
.
Challenges in iodine-125 sources production for cancer treatment.
In: INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 25-25.
Abstract:
There is a great challenge the implantation on assurance quality system in the brachytherapy
sources production. It involves tofulfill the Good Manufacturing Practices (GMPs) requirements,
involving the process validation and of all supporting activities such as cleaning and sanitization.
The purpose of this work was to execute a process validation in the iodine-125 seeds production
on Radiation Technology Center located at IPEN- Brazil. Besides this, the sanitization was to
evaluate the effectiveness of different surface cleaning products, determining the best to reduce
radiological contamination to acceptable levels during the sources production, according to
legislation. The fabrication process was performed three times for evaluation. The parameters
evaluated in this study were: the source welding efficiency and the leakage tests results (immersion
test). The welding efficiency doesn’t have an established parameter, since is visually evaluated by
the operator, and the leakage detection has to be under 5 nCi / 185 Bq, accordingly with the ISO
9978. In the relation of sanitization, it was established a cleaning program for three production lots
of iodine 125 seeds using three types of sanitizers: Lot 1 with extran 1/1 (v/v), Lot 2 with hydrogen
peroxide 6% and Lot 3 with sodium hydroxide 1M. Each lots contained seven iodine 125 seeds
and was immersed in the sanitizer for 1 hour and then two washes with distilled water. An activity
detected in each lots does not exceed 0,2 kBq (˭5nCi). The observed values on process validation
were: 75% welding efficiency and 32% leakage detection. Although established values for the
global efficiency aren’t available in the literature, the results showed high consistency and
acceptable percentages, especially when other similar manufacturing processes are used in
comparison (average 85-70% found in the literature for other similar metallic structures).
According to results of sanitization, the best choice for remove de surface contamination was
peroxide hydrogen. Further testing should ensure the sanitizer's choice is based not only on the
removal of surface contamination, but also this sanitizer does not leave residues requiring further
rinsing with distilled water. Those values will be important data when drafting the validation
document and to follow the Good Manufacturing Practices (GMPs).
FEHER, ANSELMO; BAPTISTA, TATYANA S.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.; MOURA, JOÃO A.
Challenges in iodine-125 sources production for cancer treatment.
In:
INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 25-25.
Disponível em: http://repositorio.ipen.br/handle/123456789/34539. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ALMEIDA, S.B.
; CUNHA, A.P.V.; TAVARES, P.V.S.
; SAMPAIO, C.C.; MENEGUSSI, G.; CAMPOS, L.L.
.
Small field dosimetry employing the thermoluminescence technique using a 3D printed phantom.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 170.
ALMEIDA, S.B.; CUNHA, A.P.V.; TAVARES, P.V.S.; SAMPAIO, C.C.; MENEGUSSI, G.; CAMPOS, L.L.
Small field dosimetry employing the thermoluminescence technique using a 3D printed phantom.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 170.
Disponível em: http://repositorio.ipen.br/handle/123456789/34538. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
DAL BELO, FELIPE
; BERNARDES, EMERSON
; NASCIMENTO, FERNANDO C.
; CALVO, WILSON A.P.
.
Application of Data Science and Artificial Intelligence in the productive efficiency of radiopharmaceuticals.
In: INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 220-220.
Abstract:
The present research addresses the application of Data Science and Artificial Intelligence in the
production processes of injectable radiopharmaceuticals in the Radiopharmacy Center, at IPENCNEN.
Center of greatest relevance and production scale in Latin America and one of the main
international ones, which is currently undergoing technological adaptation of its production
processes.
Given the economic and therapeutic importance of the Nuclear Medicine market in global health
systems, valued at USD 5,351.90 million in 2017, it is estimated that it will reach USD 9,981.30
million by 2026, growing at an annual rate. Average of 7.2% over the forecast period.
As a main objective, the study proposes to develop and obtain an innovative operating model
applying automation, Artificial Intelligence resources and Data Science techniques (analytics), to
make the routine of processes and operational indicators safer, predictable, effective and efficient.
This Doctoral study will provide the scientific community of medicine and nuclear technology
with the benefits and returns of the application of artificial intelligence and data science in critical
regulatory, diagnostic and therapeutic activities. And the results will lead to the Radiopharmacy
Center, modernization, innovation and a differential in the practices of its core activities.
Therefore, it is expected to implement through these technologies the improvement in the critical
stages of its production processes, combined with the digital trends of efficiency and good
manufacturing practices.
DAL BELO, FELIPE; BERNARDES, EMERSON; NASCIMENTO, FERNANDO C.; CALVO, WILSON A.P.
Application of Data Science and Artificial Intelligence in the productive efficiency of radiopharmaceuticals.
In:
INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 220-220.
Disponível em: http://repositorio.ipen.br/handle/123456789/34537. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BALOGH, TATIANA S.
; MARQUES, FABIO N.
; KADLUBOWSKI, SLAWOMIR
; LUGAO, ADEMAR B.
.
Direct radiolabeling of PVP-nanogel from 99mTcO4: reaction.
In: INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 255-255.
Abstract:
Nanogels are considered promising drug delivery systems for different pathologies, mainly associated with
neurological disease, by intranasal administration since drug transport occurs via the olfactory nerve,
causing rapid delivery to the brain. The present work aimed to evaluate a protocol for 99mTc labeling of
poly(N-vinylpyrrolidone) (PVP) nanogel synthesized by an electron beam for future in vivo biodistribution
assays. 10 mM PVP K-90 solution saturated with N2O was irradiated by e-beam using a dose of 7 kGy and
a dose rate of 5.35 kGy/s. Nanoparticles characteristic was evaluated by DLS technique to determine the
Rh and SLS to determine the Mw and Rg. Rg/Rh and ρcoil were calculated. The sample was
morphologically characterized using AFM. The same analyzes were performed with a non-irradiated PVP
solution. Radiolabeling was performed by mixing 0.55 mg of SnCl2.2H2O in 50 μL of HCl 0.1 M with (A)
450 μL 0.2 M NaOAc buffer, pH 4.1; (B) 200 μL 0.2 M NaOAc buffer, pH 4.1 and 0.5 M NaHCO3 buffer,
pH 7.26; (C) filtered solution B in a 0.22 μm syringe filter. To the solutions (A), (B), and (C) were added
200 μL of nanogel (8.9 mg of PVP K-90), 100 μL of 99mTcO4- (860-980 μCi), and the samples were
stirred at 500 rpm for 90 minutes at room temperature. The reaction was assessed by W3MM paper/acetone
chromatography at the end of the process. All solutions were filtered through a 0.22 μm filter to remove
99mTcO2, as a previously validated process, and the radioactivity in the filter and the solution was
measured. Finally, the solutions were concentred in the Amicon® (10 kD), and the radioactivity of the
filtered and retained solution were measured too. The solution remaining on the filter was diluted with 300
μl of purified water and the concentration process was repeated twice. Filter content and the sum of filtered
solutions 1 and 2 had the radioactivity measured to check labeling efficiency. Nanogel was obtained with
an average for Rh of 12.49 nm, Rg of 6.8 nm, Mw of 1.32 x 106 g/mol, ρcoil of 786.98, and Rg/Rh of
0.620. High relief spherical structures were observed in the AFM images instead of the low roughness film
observed in the non-irradiated PVP solution. Chromatographic analysis of the sample prepared only with
NaOAc buffer (final pH 3.8) and of the sample with the mixture of buffers without previous filtration (final
pH 6.8) indicated, respectively, 99.89 and 99.68% associated with the formation of 99mTc-PVP nanogel
or 9mTc-colloid. In contrast, the sample prepared with the mixture of buffers and previously filtered (final
pH 6.8) showed 80.10% of nonreduced 99mTcO4. Filtration results at 0.22 μm showed that the 9mTccolloid
remains 100% retained in the filter, while free 99mTcO4 and 99mTc-PVP nanogel are filtered.
Amicon® filtration confirmed 95.75% and 92% of 99mTc-PVP nanogel formation in the samples with
NaOAc buffer and a mixture of buffers without previous filtration, respectively. It was possible to
synthesize nanogel by electron beam, obtaining an average Rh of 12.49 nm. The labeling process with
99mTcO4- showed a high radiochemical yield in samples prepared with NaOAc buffer and a mixture of
buffers without previous filtration.
BALOGH, TATIANA S.; MARQUES, FABIO N.; KADLUBOWSKI, SLAWOMIR; LUGAO, ADEMAR B.
Direct radiolabeling of PVP-nanogel from 99mTcO4: reaction.
In:
INTERNATIONAL SYMPOSIUM ON TRENDS IN RADIOPHARMACEUTICALS,
April 17-21, 2023,
Vienna, Austria.
Abstract...
Vienna, Austria: International Atomic Energy Agency - IAEA,
2023.
p. 255-255.
Disponível em: http://repositorio.ipen.br/handle/123456789/34536. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ANTONIO, PATRICIA L.
; SILVEIRA, IURY S.
; CALDAS, LINDA V.E.
.
OSL and PTOSL of dosimetric materials: observation of the luminescence after exposure to 90Sr+90Y source and LEDs in ultraviolet range.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 124.
ANTONIO, PATRICIA L.; SILVEIRA, IURY S.; CALDAS, LINDA V.E.
OSL and PTOSL of dosimetric materials: observation of the luminescence after exposure to 90Sr+90Y source and LEDs in ultraviolet range.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 124.
Disponível em: http://repositorio.ipen.br/handle/123456789/34535. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ZAMBONI, CIBELE B.
; GIOVANNI, DALTON N.S.
; KOKA, ANA C.
; STANOJEV, MARCO
.
Young Scientist Project presents Neutron Life.
In: ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Abstract:
The Young Scientist Project was created in 2019, by the team of the Spectroscopy and
Spectrometry of Radiation Laboratory (LEER/IPEN), with the proposal to implement nuclear
knowledge in academia and for the general public. The objective is to develop alternative
proposals for knowledge, application and dissemination of nuclear physics using social
networks. The website www.jovemcientista.com.br design involves four menus: REPORTS
where researchers talk about their career and perspectives in the field; NUCLEAR MINUTE:
where nuclear physics concepts are covered in one-minute videos; CURIOSITIES: a space
where various themes are presented, including several nuclear applications; INTERVIEWS:
conducted by students to discuss its work and a COMMUNICATION CHANNEL with the
entire team. All activities involve the participation of students from scientific initiation to
post-doc and the content produced is available on social networks YouTube (Jovem Cientista),
Instagram (@jovemcientista.com.br) associated with a Facebook page Facebook
(@jovemcientista.com.br), TikTok (@jovemcientista.com.br) and by LinkedIn and Twitter in the
editors’; profile. Now, we are present a new menu NEUTRON LIFE whose content is
produced mainly for graduate students. The idea is to present topics related to neutron physics
in a relaxed way, through the elaboration of videos and comic strips. Since the
implementation of the Young Scientist Project, interaction with students and the public has
been positive, helping to demystify and disseminate nuclear physics.
ZAMBONI, CIBELE B.; GIOVANNI, DALTON N.S.; KOKA, ANA C.; STANOJEV, MARCO.
Young Scientist Project presents Neutron Life.
In:
ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34534. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FRANÇA, MARIA B.A.; ANTONIO, PATRICIA L.
; NASCIMENTO, ERIBERTO O.; CALDAS, LINDA V.E.
; OLIVEIRA, LUCAS N. de.
Natural detector irradiated with blue LEDs for measurements in Photodynamic Therapy (PDT) via Spectroscopy (UV-Vis), Design of Experiments (DOE) and Multiple Linear Regression (MLR).
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 75.
FRANÇA, MARIA B.A.; ANTONIO, PATRICIA L.; NASCIMENTO, ERIBERTO O.; CALDAS, LINDA V.E.; OLIVEIRA, LUCAS N. de.
Natural detector irradiated with blue LEDs for measurements in Photodynamic Therapy (PDT) via Spectroscopy (UV-Vis), Design of Experiments (DOE) and Multiple Linear Regression (MLR).
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 75.
Disponível em: http://repositorio.ipen.br/handle/123456789/34533. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ZAMBONI, CIBELE B.
; SILVA, DALTON G.N. da
; BOGNAR, MARTA L.; SILVA NETO, GALDINO V. da.
Multi-analytical X-ray study of the honorary decoration of the Order of Christ.
In: ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Abstract:
The analysis of cultural heritage objects can generate information about techniques of
minting of the time, giving information not only on chronology but also regarding
preparation methodology, and provenance. In this investigation, three honorable mentions
(metal artifacts) of the order of Christ (cross, lady's and gentlemen's medal) were
performed using Energy Dispersive X-ray Fluorescence (EDXRF) technique. This
analysis were performed with a portable Amptek assemble of Si-drift XR-100SSD (25
mm2 × 500 μm) detector, equipped with a 12.5 μm Be entrance window, pre-amplifier
and digital pulse multichannel processor and Ag target. Analytical parameters were 5 μA
and 30 kV for 180 s at 2 mm distance to the target. Points distributed in distinct parts were
analyzed in each of the metal artifact. The WinQxas software was employed for spectral
analyses. These data provide to curators and historians knowledge for cataloging and
subsidies for correct storage. In addition, they can be used to identify forgeries (heritage
appreciation).
ZAMBONI, CIBELE B.; SILVA, DALTON G.N. da; BOGNAR, MARTA L.; SILVA NETO, GALDINO V. da.
Multi-analytical X-ray study of the honorary decoration of the Order of Christ.
In:
ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34532. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, DALTON G.N. da
; ZAMBONI, CIBELE B.
; PECEQUILO, BRIGITTE R.S.
; ESPOSITO, SELENE E.; PIMENTA, DANIEL C.; SIMONS, SIMONE M..
Multielemental characterization of the pollen produced by Scaptotrigona aff postica bee from Brazil using EDXRF technique.
In: ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Abstract:
The objective of this investigation was to perform a multielemental characterization of the
pollen produced by Scaptotrigona aff Postiça Bee (popularly known as “tubi”). In recent
years, the demand for natural and healthy products has grown significantly and products from
Meliponiculture (creation of stingless bees) have started to be consumed on a larger scale in
Brazil. Specifically, pollen has gained prominence in the nutritional field for being a protein
source and rich in carbohydrates, lipids, mineral trace elements, fibers, hormones and
vitamins, but scientific research is still scarce, especially regarding studies of its specific
composition. The aim of this investigation was to evaluate the content of inorganic elements
(multielemental analysis) in pollen from “tubi” bees. Pollen samples were collected during a
one year, in a meliponary of Barra do Corda city, in the state of Maranhão. The EDXRF
analyzes were carried out using an X-Ray Fluorescence spectrometer (X-123SDD, Amptek),
constituted by a Silicon detector coupled a mini X-ray tube (Ag). These data are the first
estimates of mineral trace elements in this natural product and provide benefits to beekeepers
regarding their characteristic specifications. In addition contributes with relevant data in the
nutritional field.
SILVA, DALTON G.N. da; ZAMBONI, CIBELE B.; PECEQUILO, BRIGITTE R.S.; ESPOSITO, SELENE E.; PIMENTA, DANIEL C.; SIMONS, SIMONE M.
Multielemental characterization of the pollen produced by Scaptotrigona aff postica bee from Brazil using EDXRF technique.
In:
ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34531. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TALACIMON, CRISTHIAN
; ILCA, MEDEIROS
; TEODORO, LARA
; RIGO, MARIA
; GESSERAME, MAYSA
; TAVARES, PAULO
; RODRIGUES, PRISCILA
; NOGUEIRA, THUANY
; ROSERO, WILMMER
; RODRIGUES JUNIOR, ORLANDO
; ZEITUNI, CARLOS
; ROSTELATO, MARIA
.
Investigating a dopant for mitigating the natural degradation of Fricke Xylenol Gel dosimeters.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ICDA,
2023.
p. 64.
TALACIMON, CRISTHIAN; ILCA, MEDEIROS; TEODORO, LARA; RIGO, MARIA; GESSERAME, MAYSA; TAVARES, PAULO; RODRIGUES, PRISCILA; NOGUEIRA, THUANY; ROSERO, WILMMER; RODRIGUES JUNIOR, ORLANDO; ZEITUNI, CARLOS; ROSTELATO, MARIA.
Investigating a dopant for mitigating the natural degradation of Fricke Xylenol Gel dosimeters.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ICDA,
2023.
p. 64.
Disponível em: http://repositorio.ipen.br/handle/123456789/34530. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, ANA C.K. de S.
; ZAMBONI, CIBELE B.
; ALMEIDA, MATEUS R. de
; SILVA, DALTON G.N. da
.
Application of the X-ray fluorescence analysis to determine the elemental composition of Brazilian Olympic coins.
In: ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Abstract:
In this investigation, the elemental composition of Brazilian Olympic coins was investigated using Energy Dispersive X-ray Fluorescence (EDXRF) analytic technique. From the release of Olympic albums (2014, 2015, and 2016) the demand for these coins has increased and some can be worth up to 7000% more than their normal value. The analysis was performed using a compact X-ray spectrometer model X-123 SDD with Ag target. The characteristic X-ray fluorescent intensity of Ka lines were measured with a Si Drift detector (25 mm² x 500 μm) with Be window (12.5 μm). For the spectrometer calibration, certified standard solutions from Z = 14 to Z = 51 were evaluated. The results were compared with coins in current circulation. All the spectral analysis was performed using WinQxas software. The spectral analysis of Olympic coins shows Cr, Mn, Fe and Cu as majorities and peaks of various elements as traces. The 2014 and 2015 Olympic coins groups exhibited similar surface compositions for majorities and trace elements (V, Ni, Mo, Ag, In, Sn, Ce, Nd, Ir and Pb), while the 2016 group coins exhibited Nb presence as a trace element. Some differences were also identified when the comparison was made with current coins. These data provide curators with information for cataloging as well as being used to identify forgeries (heritage appreciation), important for collectors.
SILVA, ANA C.K. de S.; ZAMBONI, CIBELE B.; ALMEIDA, MATEUS R. de; SILVA, DALTON G.N. da.
Application of the X-ray fluorescence analysis to determine the elemental composition of Brazilian Olympic coins.
In:
ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34529. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, THALES Z. dos S. de
; ZAMBONI, CIBELE B.
.
Analysis of Ca and Fe in supplements by EDXRF technique.
In: ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Abstract:
Measurements of the elemental composition of supplements is relevant in the nutritionalcontext for the consumer, as well as for the professional for the correct prescription, since thenational legislation still does not oblige the manufacturer to determine the content ofminerals, with the exception of sodium. According to Euromonitor (market research onconsumer products, commercial industries, demographics trends and consumer lifestyles inBrasil) the most consumed minerals were calcium (13%), followed by iron (4%). Anothermarket research carried out at the end of 2020 by “Associação Brasileira da Indústria deAlimentos para Fins Especiais e Congêneres” (Abiad) also emphases that consumption ofdietary supplements increased by 10% in the last five years in Brazil. In this study, the Ca andFe content in food supplements commercially available at São Paulo city were evaluatedusing the Energy Dispersion X-Ray Fluorescence (FRX-ED) technique. The data wereobtained using a compact X- Ray spectrometer (X-123 SDD, Amptek) constituted by a SDDdetector coupled a mini X-ray tube (Ag). Concentration results were compared with thoseprovided by the manufacturer.
OLIVEIRA, THALES Z. dos S. de; ZAMBONI, CIBELE B.
Analysis of Ca and Fe in supplements by EDXRF technique.
In:
ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34528. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GOES, MARIA P. de O.
; BENEDITO, MARIA G.M.
; CAMPOS, DANIEL de O.
; ZAMBONI, CIBELE B.
.
Establishment of zinc concentrations in blood of elite runners by NAA.
In: ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Abstract:
The purpose of this study was to use Neutron Activation Analysis (NAA) to investigate Zn levels in blood of elite athletes (long-distance runners), and compared with a reference population. Zinc is a co-factor for numerous enzymes implicated in several physiological processes, DNA reproduction, cellular respiration, endocrine system, and immune response. High aerobic activity and dietary habits may result in the depletion of body zinc stores, which could decrease aerobic performance, increasing the risks of fatigue and immune disorders. In this study, samples were collected from 10 elite athletes (6 men and 4 women), in constant training for the last 6 years, and 58 healthy individuals (30 men and 28 women) of the same age but not involved in physical activities. The samples were irradiated in the IEA-R1 nuclear reactor (3.5-4.0 MW, pool type) at IPEN. The comparison for female groups (control and athletes) exhibited a decrease in Zn concentrations. Furthermore, the blood Zn concentrations in athletes are higher in men than in women. These data can be considered for the preparation of a balanced diet, for evaluating the performance of the athletes during the competitive period as well as, to present a new evaluation of clinical protocol using NAA technique.
GOES, MARIA P. de O.; BENEDITO, MARIA G.M.; CAMPOS, DANIEL de O.; ZAMBONI, CIBELE B.
Establishment of zinc concentrations in blood of elite runners by NAA.
In:
ENCONTRO DE PRIMAVERA DA SOCIEDADE BRASILEIRA DE FÍSICA, 3.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 45.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 42.,
26-29 de setembro, 2023,
Niterói, RJ.
Resumo...
São Paulo, SP: Sociedade Brasileira de Física,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34527. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MEDEIROS, ILCA M.A.M.
; SILVA, ANA C.K. de S.
; TALACIMON, CRISTHIAN F.
; MOURA, JOAO A.
; TEODORO, LARA E.H.
; RIGO, MARIA E.Z.
; RODRIGUES, PRISCILA S.
; ROSERO, WILMMER A.A.
; ROSTELATO, MARIA E.C.M.
; ZEITUNI, CARLOS A.
.
How to select a dosimeter?.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 217.
MEDEIROS, ILCA M.A.M.; SILVA, ANA C.K. de S.; TALACIMON, CRISTHIAN F.; MOURA, JOAO A.; TEODORO, LARA E.H.; RIGO, MARIA E.Z.; RODRIGUES, PRISCILA S.; ROSERO, WILMMER A.A.; ROSTELATO, MARIA E.C.M.; ZEITUNI, CARLOS A.
How to select a dosimeter?.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 217.
Disponível em: http://repositorio.ipen.br/handle/123456789/34526. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TALACIMON, CRISTHIAN
; MEDEIROS, ILCA
; TEODORO, LARA
; RIGO, MARIA
; GESSERAME, MAYSA
; TAVARES, PAULO
; RODRIGUES, PRISCILA
; NOGUEIRA, THUANY
; ROSERO, WILMMER
; RODRIGUES JUNIOR, ORLANDO
; ZEITUNI, CARLOS
; ROSTELATO, MARIA ELISA CHUERY MA
.
Feasibility study of fricke xylenol gel as a dosimeter for low dose rate brachytherapy sources.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 63.
TALACIMON, CRISTHIAN; MEDEIROS, ILCA; TEODORO, LARA; RIGO, MARIA; GESSERAME, MAYSA; TAVARES, PAULO; RODRIGUES, PRISCILA; NOGUEIRA, THUANY; ROSERO, WILMMER; RODRIGUES JUNIOR, ORLANDO; ZEITUNI, CARLOS; ROSTELATO, MARIA ELISA CHUERY MA.
Feasibility study of fricke xylenol gel as a dosimeter for low dose rate brachytherapy sources.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 63.
Disponível em: http://repositorio.ipen.br/handle/123456789/34525. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GONCALVES, JOSEMARY A.C.
; MANGIAROTTI, ALESSIO; SOMESSARI, ELIZABETH S.R.
; NAPOLITANO, CELIA M.
; BUENO, CARMEN C.
.
Online electron beam monitoring with a diode-based dosimetry system in routine quality control.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 119.
GONCALVES, JOSEMARY A.C.; MANGIAROTTI, ALESSIO; SOMESSARI, ELIZABETH S.R.; NAPOLITANO, CELIA M.; BUENO, CARMEN C.
Online electron beam monitoring with a diode-based dosimetry system in routine quality control.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 119.
Disponível em: http://repositorio.ipen.br/handle/123456789/34524. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SANTOS, S.C.
; RODRIGUES JUNIOR, O.
; CAMPOS, L.L.
.
EPR characterization of thulium-yttria micro rods.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 118.
SANTOS, S.C.; RODRIGUES JUNIOR, O.; CAMPOS, L.L.
EPR characterization of thulium-yttria micro rods.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 118.
Disponível em: http://repositorio.ipen.br/handle/123456789/34523. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PINTO, MAYARA S.
; ROSERO, WILMMER A.A.
; ROSTELATO, MARIA E.M.C.
; RIBEIRO, MARTHA S.
.
Photobiomodulation therapy combined with radioactive gold nanoparticles in breast cancer-bearing mice.
In: ANNUAL MEETING OF THE BRAZILIAN BIOPHYSICAL SOCIETY, 47th,
October 19-22, 2023,
Campinas, SP.
Abstract...
Campinas, SP: Galoá,
2023.
Abstract:
Breast cancers are responsible for the highest number of worldwide deaths among
women requiring new therapeutic strategies to promote better life’s quality and survival rates for patients. Nanobrachytherapy (NB) and photobiomodulation therapy (PBM) emerge in this context as less invasive approaches for breast cancer treatment. NB is a technique that might deliver high doses of ionizing radiation in a shorter time and in a localized way in comparison to conventional radiotherapy and PBM could enhance cell sensitivity when applied before NB. In this work, we aim to investigate the impact of PBM combined with NB involving radioactive gold nanoparticles (AuNPs) in the treatment of breast cancer in a murine model. Murine 4T1 cells were cultivated in RPMI medium and after injected into the lower-left mammary fat pad animals’ breast. When the tumor reached approximately 0.1 cm3, AuNPs (~284 microCi) were inoculated in the mouse breast. Thereafter, the tumor was irradiated with a red LED (660 nm, 40 mW, 150 s, 6 J) in a single application. Animals were monitored for 3 weeks until euthanasia. Our results demonstrated an arrestment in tumor growth for NB group in comparison to Control, PBM and PBM + NB groups. These data suggest that a single PBM session was not able to enhance the NB of breast cancer. The following steps will involve applying NB and PBM in two sessions. The first session will take place on the same day as NB application, and the second one after 6 days, corresponding to two half-lives of 198AuNPs.
PINTO, MAYARA S.; ROSERO, WILMMER A.A.; ROSTELATO, MARIA E.M.C.; RIBEIRO, MARTHA S.
Photobiomodulation therapy combined with radioactive gold nanoparticles in breast cancer-bearing mice.
In:
ANNUAL MEETING OF THE BRAZILIAN BIOPHYSICAL SOCIETY, 47th,
October 19-22, 2023,
Campinas, SP.
Abstract...
Campinas, SP: Galoá,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34522. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, ABDENEGO R.
; CABRAL, FERNANDA V.
; SILVA, CAMILA R.
; SILVA, DANIELA F.T.
; FREITAS, ANDERSON Z.
; FONTES, ADRIANA; RIBEIRO, MARTHA S.
.
Photodynamic inactivation against the critical priority pathogen Candida auris.
In: ANNUAL MEETING OF THE BRAZILIAN BIOPHYSICAL SOCIETY, 47th,
October 19-22, 2023,
Campinas, SP.
Abstract...
Campinas, SP: Galoá,
2023.
Abstract:
Fungal pathogens and their associated infections present a growing challenge to global public health. Among these pathogens, Candida auris has emerged as a highly hazardous hospital-acquired microorganism, included in the critical priority group by the World Health Organization. Methylene Blue (MB) is a widely acknowledged photosensitizer utilized in antifungal photodynamic inactivation (PDI) and holds significant clinical applications. The MB methylation results in the formation of a more lipophilic compound, the 1,9-dimethyl MB (DMMB), which can have an enhanced interaction with cell membranes. Nevertheless, PDI mediated by DMMB to combat fungi remains little explored. In this study, we assessed the impact and underlying mechanisms of PDI using MB (MB-PDI) or DMMB (DMMB-PDI) combined with a red LED against C. auris. PDI was conducted on the CBS 10913 strain of C. auris, utilizing different concentrations of MB (0 – 100 μM) or DMMB (0 – 3 μM) at light doses of 10 or 30 J/cm². To evaluate the PDI efficacy, we measured colony-forming units and monitored reactive oxygen species (ROS) production. Additionally, we assessed lipid peroxidation (LPO) and mitochondrial membrane potential (ΔΨm) to gain insights into the differences between MB and DMMB. Our findings revealed that DMMB-PDI successfully eradicated C. auris yeasts at 3 μM concentration, irrespective of the light dose, whereas MB (100 μM) only exhibited cell eradication at the highest light dose. ROS formation was more pronounced for DMMB than MB at 10 J/cm2. At 30 J/cm2, MB and DMMB produced similar ROS levels. In sublethal conditions, DMMB-PDI induced significantly higher LPO, and ΔΨm levels compared to MB-PDI. Furthermore, DMMB-PDI effectively inhibited biofilm formation and disrupted mature biofilms, with no observed toxicity in fibroblast cells. In conclusion, our study demonstrates the potential of DMMB-PDI as a promising weapon to combat the global priority pathogen C. auris. The enhanced PDI efficacy and biofilm eradication capacity of DMMB make it a valuable candidate for further exploration in the fight against this hazardous pathogen. As the incidence of drug-resistant fungal infections continues to rise, the development of innovative and effective therapeutic strategies like DMMB-PDI is crucial in safeguarding public health worldwide.
SILVA, ABDENEGO R.; CABRAL, FERNANDA V.; SILVA, CAMILA R.; SILVA, DANIELA F.T.; FREITAS, ANDERSON Z.; FONTES, ADRIANA; RIBEIRO, MARTHA S.
Photodynamic inactivation against the critical priority pathogen Candida auris.
In:
ANNUAL MEETING OF THE BRAZILIAN BIOPHYSICAL SOCIETY, 47th,
October 19-22, 2023,
Campinas, SP.
Abstract...
Campinas, SP: Galoá,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34521. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
LIMA, GEYSE S. de; SOUZA, SUEDEN O. de; RAPOSO, BRUNO L.; SANTANA, GLEYCIANE S. de; SARMENTO-NETO, JOSE F.; SANTOS, BEATE S.; NEVES, REJANE P.; RIBEIRO, MARTHA S.
; REBOUCAS, JULIO S.; CABRAL FILHO, PAULO E.; FONTES, ADRIANA.
Photodynamic inactivation of Candida glabrata boosted by association of silver nanoparticles with cationic ZnTE-2-PyP4+ porphyrin.
In: ANNUAL MEETING OF THE BRAZILIAN BIOPHYSICAL SOCIETY, 47th,
October 19-22, 2023,
Campinas, SP.
Abstract...
Campinas, SP: Galoá,
2023.
Abstract:
Candida glabrata, a high priority fungal pathogen, presents alarming incidence and resistance potential to available antifungals. In this scenario, photodynamic inactivation (PDI) introduces a promising antifungal approach, especially in resistant cases. PDI occurs when a photosensitizer (PS) is excited by an appropriate light source, leading to production of reactive oxygen species (ROS). Zinc porphyrins (ZnPs) are attractive PSs for their efficient ROS generation and cellular uptake. The plasmonic effect of silver nanoparticles (AgNPs) can be explored to potentiate the action of PSs, such as ZnPs, in PDI. Therefore, this work aimed to study the association of AgNPs with ZnTE-2-PyP4+ (ZnP-ethyl) in PDI against C. glabrata. AgNPs were synthesized and characterized by absorption spectroscopy and electron microscopy. The association AgNP:ZnP-ethyl was evaluated by zeta potential (ζ) analyses as well as absorption and emission spectroscopies. The systems containing AgNP:ZnP-ethyl (at different proportions; v/v) and different ZnP-ethyl concentrations (0.5 – 1.5 µM) were prepared and incubated with a resistant isolate of C. glabrata, followed by illumination with a blue LED. The PDI effect was assessed by quantifying colony forming units. AgNPs presented spherical morphology and extinction maximum at ~410 nm, overlapping with the ZnP-ethyl absorption spectra. Variations in ζ confirmed the association between AgNPs and ZnP-ethyl, corroborated by subtle changes in the ZnP spectroscopic profile. The AgNP:ZnP-ethyl systems promoted complete fungal eradication at 0.6 µM, while at 0.5 µM they promoted yeast reduction of ca. 5.7 log10 (1:4; v/v) and 6.8 log10 (4:1; v/v). Illuminated AgNPs had no antimicrobial effect alone, and individual ZnP-ethyl (1.5 µM) promoted a 2 log10 reduction. These results show the benefit of AgNPs:ZnP-ethyl association to boost PDI efficiency against resistant C. glabrata isolates. This is a promising antifungal approach to treat resistant candidiasis.
LIMA, GEYSE S. de; SOUZA, SUEDEN O. de; RAPOSO, BRUNO L.; SANTANA, GLEYCIANE S. de; SARMENTO-NETO, JOSE F.; SANTOS, BEATE S.; NEVES, REJANE P.; RIBEIRO, MARTHA S.; REBOUCAS, JULIO S.; CABRAL FILHO, PAULO E.; FONTES, ADRIANA.
Photodynamic inactivation of Candida glabrata boosted by association of silver nanoparticles with cationic ZnTE-2-PyP4+ porphyrin.
In:
ANNUAL MEETING OF THE BRAZILIAN BIOPHYSICAL SOCIETY, 47th,
October 19-22, 2023,
Campinas, SP.
Abstract...
Campinas, SP: Galoá,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34520. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
RIGO, MARIA
; ANGELOCCI, LUCAS
; RODRIGUES, PRISCILA
; TALACIMON, CRISTHIAN
; MEDEIROS, ILCA
; TEODORO, LARA
; NOGUEIRA, THUANY
; ROSERO, WILMMER
; ZEITUNI, CARLOS
; ROSTELATO, MARIA
.
Dosimetric approach of Au-198 nanoparticles with radiochromic film.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 57.
RIGO, MARIA; ANGELOCCI, LUCAS; RODRIGUES, PRISCILA; TALACIMON, CRISTHIAN; MEDEIROS, ILCA; TEODORO, LARA; NOGUEIRA, THUANY; ROSERO, WILMMER; ZEITUNI, CARLOS; ROSTELATO, MARIA.
Dosimetric approach of Au-198 nanoparticles with radiochromic film.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 57.
Disponível em: http://repositorio.ipen.br/handle/123456789/34519. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MARTINS, ELAINE W.
; POTIENS, MARIA P.A.
.
Performance evaluation of activity meters using the in-situ calibration methodology with 99mTc.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 56.
MARTINS, ELAINE W.; POTIENS, MARIA P.A.
Performance evaluation of activity meters using the in-situ calibration methodology with 99mTc.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 56.
Disponível em: http://repositorio.ipen.br/handle/123456789/34517. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GONCALVES, JOSEMARY A.C.
; MANGIAROTTI, ALESSIO; POTIENS, MARIA P.A.
; CALDAS, LINDA V.E.
; BUENO, CARMEN C.
.
Dosimetric parameters and radiation tolerance of epitaxial diodes for diagnostic radiology and computed tomography X-rays.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ICDA,
2023.
p. 49.
GONCALVES, JOSEMARY A.C.; MANGIAROTTI, ALESSIO; POTIENS, MARIA P.A.; CALDAS, LINDA V.E.; BUENO, CARMEN C.
Dosimetric parameters and radiation tolerance of epitaxial diodes for diagnostic radiology and computed tomography X-rays.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ICDA,
2023.
p. 49.
Disponível em: http://repositorio.ipen.br/handle/123456789/34515. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
VILLANI, DANIEL
; SAVI, M.; RODRIGUES JUNIOR, O.
; POTIENS, M.P.A.
; CAMPOS, L.L.
.
Computed Tomography Imaging analysis of a fused
filament fabrication (FFF) 3D printed neck-thyroid
phantom for multidisciplinary purposes.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 42.
VILLANI, DANIEL; SAVI, M.; RODRIGUES JUNIOR, O.; POTIENS, M.P.A.; CAMPOS, L.L.
Computed Tomography Imaging analysis of a fused
filament fabrication (FFF) 3D printed neck-thyroid
phantom for multidisciplinary purposes.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 42.
Disponível em: http://repositorio.ipen.br/handle/123456789/34513. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GODELI NETO, JULIO; POLETTI, MARTIN E.; CUNHA, DIEGO M. da; POTIENS, MARIA da P.A.
.
Computational evaluation of the bucky components influence on the estimation of normalized glandular dose in digital mammography.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 69.
GODELI NETO, JULIO; POLETTI, MARTIN E.; CUNHA, DIEGO M. da; POTIENS, MARIA da P.A.
Computational evaluation of the bucky components influence on the estimation of normalized glandular dose in digital mammography.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 69.
Disponível em: http://repositorio.ipen.br/handle/123456789/34512. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ALMEIDA JUNIOR, J.N.
; POTIENS, M.P.A.
; RODRIGUES JUNIOR, O.
.
Characterization of a 3D Prototyping Semi-Automated Filter Holder System for RQR and RQA radiation qualities.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 172.
ALMEIDA JUNIOR, J.N.; POTIENS, M.P.A.; RODRIGUES JUNIOR, O.
Characterization of a 3D Prototyping Semi-Automated Filter Holder System for RQR and RQA radiation qualities.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 172.
Disponível em: http://repositorio.ipen.br/handle/123456789/34511. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
RODRIGUES, PRISCILA
; BURIN, ANA
; BARBEZAN, ANGELICA
; TALACIMON, CRISTHIAN
; ILCA, MEDEIROS
; TEODORO, LARA E.H.
; RIGO, MARIA
; GESSERAME, MAYSA
; TAVARES, PAULO
; NOGUEIRA, THUANY
; ROSERO, WILMMER
; RODRIGUES JUNIOR, ORLANDO
; ZEITUNI, CARLOS
; ROSTELATO, MARIA
.
Characterization of FXG dosimeters with gold nanoparticles for brachytherapy applications.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 67.
RODRIGUES, PRISCILA; BURIN, ANA; BARBEZAN, ANGELICA; TALACIMON, CRISTHIAN; ILCA, MEDEIROS; TEODORO, LARA E.H.; RIGO, MARIA; GESSERAME, MAYSA; TAVARES, PAULO; NOGUEIRA, THUANY; ROSERO, WILMMER; RODRIGUES JUNIOR, ORLANDO; ZEITUNI, CARLOS; ROSTELATO, MARIA.
Characterization of FXG dosimeters with gold nanoparticles for brachytherapy applications.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 67.
Disponível em: http://repositorio.ipen.br/handle/123456789/34510. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, IANDRA T.; PIERI, KAREN; ALBINO, LUCAS D.; FONTANA, THIAGO S.; SANTOS, MATHEUS F. dos; ROESLER, ERNESTO; ASFORA, VIVIANE K.; OLIVEIRA, CHARLES; GONCALVES, JOSEMARY A.C.
; BUENO, CARMEN C.
; KHOURY, HELEN J..
Characterization of a commercial PIN diode for radiotherapy photon beam dosimetry.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 47.
SILVA, IANDRA T.; PIERI, KAREN; ALBINO, LUCAS D.; FONTANA, THIAGO S.; SANTOS, MATHEUS F. dos; ROESLER, ERNESTO; ASFORA, VIVIANE K.; OLIVEIRA, CHARLES; GONCALVES, JOSEMARY A.C.; BUENO, CARMEN C.; KHOURY, HELEN J.
Characterization of a commercial PIN diode for radiotherapy photon beam dosimetry.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 47.
Disponível em: http://repositorio.ipen.br/handle/123456789/34509. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SUZART, KAROLINE F.
; PEREIRA, MARIA da C.
; MESQUITA, CARLOS H. de
; POTIENS, MARIA da P.A.
.
Development and Characterization of the CsI:Tl scintillator grown by the Bridgman technique for use as a radiation detector.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 46.
SUZART, KAROLINE F.; PEREIRA, MARIA da C.; MESQUITA, CARLOS H. de; POTIENS, MARIA da P.A.
Development and Characterization of the CsI:Tl scintillator grown by the Bridgman technique for use as a radiation detector.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 46.
Disponível em: http://repositorio.ipen.br/handle/123456789/34508. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TAVARES, P.V.S.
; DINIZ, R.E.
; RODRIGUES JUNIOR, O.
; CAMPOS, L.L.
.
Attenuation images of Optical CT using Fricke xylenol solution for dose mapping in radiotherapy.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 61.
TAVARES, P.V.S.; DINIZ, R.E.; RODRIGUES JUNIOR, O.; CAMPOS, L.L.
Attenuation images of Optical CT using Fricke xylenol solution for dose mapping in radiotherapy.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 61.
Disponível em: http://repositorio.ipen.br/handle/123456789/34507. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, LUCAS N. de
; NASCIMENTO, ERIBERTO O.; ANTONIO, PATRICIA L.
; CALDAS, LINDA V.E.
.
A new natural detector (Curcuma Longa L.) for photodynamic therapy (PDT) measurements with blue LED irradiations: Application of Convolutional Neural Networks (CNN) and Multilayer Perceptron (MLP).
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 71.
OLIVEIRA, LUCAS N. de; NASCIMENTO, ERIBERTO O.; ANTONIO, PATRICIA L.; CALDAS, LINDA V.E.
A new natural detector (Curcuma Longa L.) for photodynamic therapy (PDT) measurements with blue LED irradiations: Application of Convolutional Neural Networks (CNN) and Multilayer Perceptron (MLP).
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 71.
Disponível em: http://repositorio.ipen.br/handle/123456789/34506. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
RODRIGUES, PRISCILA
; BURIN, ANA
; TALACIMON, CRISTHIAN
; AMARAL, ILCA MARLI
; PEREIRA, JULIO
; TEODORO, LARA E.H.
; RIGO, MARIA
; TAVARES, PAULO
; MARTINS, ANNA; RODRIGUES JUNIOR, ORLANDO
; SOUZA, CARLA de
; ZEITUNI, CARLOS
; ROSTELATO, MARIA
.
Validation of Fricke xylene gel dosimetry through comparisons between MCNP and TOPAS simulations.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 175.
RODRIGUES, PRISCILA; BURIN, ANA; TALACIMON, CRISTHIAN; AMARAL, ILCA MARLI; PEREIRA, JULIO; TEODORO, LARA E.H.; RIGO, MARIA; TAVARES, PAULO; MARTINS, ANNA; RODRIGUES JUNIOR, ORLANDO; SOUZA, CARLA de; ZEITUNI, CARLOS; ROSTELATO, MARIA.
Validation of Fricke xylene gel dosimetry through comparisons between MCNP and TOPAS simulations.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 175.
Disponível em: http://repositorio.ipen.br/handle/123456789/34501. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OTERO, ANDRE G.L.
; MARUMO, JULIO T.
; JUNIOR POTIENS, ADEMAR J.
.
A methodology for automated radioactive waste characterization.
In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 174.
OTERO, ANDRE G.L.; MARUMO, JULIO T.; JUNIOR POTIENS, ADEMAR J.
A methodology for automated radioactive waste characterization.
In:
INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 4th,
October 16-20, 2023,
Valencia, Spain.
Abstract...
Valencia, Spain: ISIRYM,
2023.
p. 174.
Disponível em: http://repositorio.ipen.br/handle/123456789/34500. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PINHEIRO, R.S.; ANA, P.A.; RIBEIRO, M.S.
; TANAKA, H..
Use of PDT therapy for symptom reduction in patients who are or have had COVID-19.
In: WORKSHOP DE ENGENHARIA BIOMEDICA, 1.,
8-9 de março, 2023,
Online.
Resumo expandido...
São Bernardo do Campo, SP: Universidade Federal do ABC,
2023.
p. 94-95.
PINHEIRO, R.S.; ANA, P.A.; RIBEIRO, M.S.; TANAKA, H.
Use of PDT therapy for symptom reduction in patients who are or have had COVID-19.
In:
WORKSHOP DE ENGENHARIA BIOMEDICA, 1.,
8-9 de março, 2023,
Online.
Resumo expandido...
São Bernardo do Campo, SP: Universidade Federal do ABC,
2023.
p. 94-95.
Disponível em: http://repositorio.ipen.br/handle/123456789/34463. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FABRETTI, L.T.; SILVA, D.F.T.
; RAELE, M.P.
; KATO, I.T..
Light-tissue interaction of laser with neonatal rat brains.
In: WORKSHOP DE ENGENHARIA BIOMEDICA, 1.,
8-9 de março, 2023,
Online.
Resumo expandido...
São Bernardo do Campo, SP: Universidade Federal do ABC,
2023.
p. 84-85.
FABRETTI, L.T.; SILVA, D.F.T.; RAELE, M.P.; KATO, I.T.
Light-tissue interaction of laser with neonatal rat brains.
In:
WORKSHOP DE ENGENHARIA BIOMEDICA, 1.,
8-9 de março, 2023,
Online.
Resumo expandido...
São Bernardo do Campo, SP: Universidade Federal do ABC,
2023.
p. 84-85.
Disponível em: http://repositorio.ipen.br/handle/123456789/34462. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TAPPIZ, B.
; SILVA, P.S.C.
; OSTERMANN, C.K.
; LIMA, N.P.
; BRAGUIN, L.N.M.
; BOTIA, S.; LEVIN, I.; BUSTILLOS, O.V.
.
Assessment of 238U and 226Ra activity concentration along the Amazon Tall Tower Observatory site.
In: INTERNATIONAL CONFERENCE ON ENVIRONMENTAL RADIOACTIVITY, 7th,
September 17-22, 2023,
Seville, Spain.
Abstract...
Seville, Spain: Universidad de Sevilla,
2023.
p. 51-51.
Abstract:
The Amazon Tall Tower Observatory (ATTO) site is a region located within the Uatumã Sustainable Development Reserve (USRD), approximately 150 km northeast of Manaus city, in the Brazilian state of Amazonas. At the ATTO site, there are 3 tall towers, which are used for studies on the Amazon rainforest and its interaction with the soil and the atmosphere. The activity concentration of 238U and 226Ra was determined in soil samples collected in the footprint of the ATTO site by gamma spectrometry. The activity concentration of these radionuclides is important for understanding the 222Rn exhalation rate and 222Rn flux from soils. Knowledge of the 222Rn flux at the ATTO site can be useful for applications in atmospheric research, e.g., the 222Rn tracer method can be used to estimate local and regional emissions of greenhouse gasses; simulating 222Rn transport is a powerful tool for evaluation and validation of transport schemes in atmospheric chemical transport models. In this study, 39 samples collected from 13 sampling sites along a transect from the ATTO site to the river were analyzed. The highest activity concentrations were found in the Igapó forest (69 ± 2 Bq/kg for 238U and 47 ± 5 Bq/kg for 226Ra), a region near the Uatumã river with prevailing flooded black-water forest, whereas the lowest activity concentrations occurred in the Campina (Savanna on white-sand soils) and Campinanara (white-sand forest) ecosystems (18 ± 1 Bq/kg for 238U and 13 ± 2 Bq/kg for 226Ra), a transition area located between river terraces and the Terra Firme forest.
TAPPIZ, B.; SILVA, P.S.C.; OSTERMANN, C.K.; LIMA, N.P.; BRAGUIN, L.N.M.; BOTIA, S.; LEVIN, I.; BUSTILLOS, O.V.
Assessment of 238U and 226Ra activity concentration along the Amazon Tall Tower Observatory site.
In:
INTERNATIONAL CONFERENCE ON ENVIRONMENTAL RADIOACTIVITY, 7th,
September 17-22, 2023,
Seville, Spain.
Abstract...
Seville, Spain: Universidad de Sevilla,
2023.
p. 51-51.
Disponível em: http://repositorio.ipen.br/handle/123456789/34457. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
DAMATTO, S.R.
; DOMINGOS, R.M.
; TEIXEIRA, L.
; ISIKI, V.L.
; ALENCAR, M.M.
; LEONARDO, L.
.
Challenges in measuring 22Na in rainfall by gamma spectrometry in the city of São Paulo, Brazil.
In: INTERNATIONAL CONFERENCE ON ENVIRONMENTAL RADIOACTIVITY, 7th,
September 17-22, 2023,
Seville, Spain.
Abstract...
Seville, Spain: Universidad de Sevilla,
2023.
p. 204-204.
Abstract:
Na-22 is a naturally occurring radionuclide of cosmogenic origin with half live of 2.6 years, being a beta and gamma emitter (541keV and 1274.5keV, respectively). This cosmogenic radionuclide is mainly formed when cosmic rays interact with argon nucleus, occurring a fragmentation of this nucleus. The process of production of 22Na occur continually in upper atmosphere, lower stratosphere and rainfall is the predominantly process of deposition of cosmogenic radionuclides in terrestrial surface. Na-22 together with 7Be (T1/2) = 53.3 d, gamma ray 476.7keV) can be used as tracers in studies of aerosol transport between layers of the atmosphere. At the same time 22Na is rarely used in these studies due to its extremely low abundance in rainfall. The objectives of this work were to present the first results 22Na activity concentration measured in rainfall collected at the IPEN campus located in São Paulo, Brazil. Large volumes of rainfall samples were collected from October 2022 to April 2023, totaling 20 samples, and 22Na activity concentration was measured by non-destructive gamma-ray spectrometry using a coaxial Be-layer HPGe detector with 46% relative efficiency and associated electronic devices and live counting time varying from 250,000 s to 500,000 s; the rainfall volumes ranged from 14 L to 164 L. The collection container was previously acidified with 1mol L-1 HNO3 to avoid loss of radionuclide by absorption on the container walls. The first eight rainfall samples were collected in a catchment area of 1m2, which was not enough to measure the radionuclide, since all the determined results were smaller than the detection limit of the methodology. After these results, it was decided to increase the catchment area by collecting rainfall samples from the roof of the laboratory building, in an area of 78 m2; the container used to collect samples from this area was also acidified with 1 mol L-1 HNO3. In this new area, 12 rainfall samples were collected, however, as the volume of rainfall was very large in the rains collected, only one sample was acidified, a rainfall of 2 mm and a volume of 98 L; in the other samples, the large volume of rain did not allow the water to become acidic because the collection container overflowed with water. In the acidified rainfall sample, the result of 0.725 ± 0.252 Bq L-1 was determined for the radionuclide 22Na. With this result, it is possible to prove the importance of both the catchment area and the acidulation of the sample in the determination of trace radionuclides in rainfall samples.
DAMATTO, S.R.; DOMINGOS, R.M.; TEIXEIRA, L.; ISIKI, V.L.; ALENCAR, M.M.; LEONARDO, L.
Challenges in measuring 22Na in rainfall by gamma spectrometry in the city of São Paulo, Brazil.
In:
INTERNATIONAL CONFERENCE ON ENVIRONMENTAL RADIOACTIVITY, 7th,
September 17-22, 2023,
Seville, Spain.
Abstract...
Seville, Spain: Universidad de Sevilla,
2023.
p. 204-204.
Disponível em: http://repositorio.ipen.br/handle/123456789/34456. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CASTRO, J.O.
; DOMINGOS, R.M.
; DAMATTO, S.R.
; RODRIGUES, C.E.C.
; ISIKI, V.L.
; NETO, J.O.A.
.
Two years of continuous monitoring of 7Be and 210Pb in rainfall collected at the IPEN campus, São Paulo, Brazil.
In: INTERNATIONAL CONFERENCE ON ENVIRONMENTAL RADIOACTIVITY, 7th,
September 17-22, 2023,
Seville, Spain.
Abstract...
Seville, Spain: Universidad de Sevilla,
2023.
p. 311-311.
Abstract:
The naturally occurring radionuclides 7Be and 210Pb are produced in the atmosphere and used as tracers of a wide variety of processes that occur in the Earth's atmosphere and surface. The cosmogenic radionuclide 7Be (T1/2 = 53.3 d), is produced in the upper atmosphere by cosmic ray spallation of oxygen and nitrogen; 210Pb (T1/2 = 22.3 y), a natural radionuclide from 238U series can be found in the atmosphere, as a product of 222Rn decay that emanates from the ground. Both natural radionuclides can be used as tracers for heavy metals and pollutants in the environment, tracer of soil erosion, transport processes in watershed and sedimentation in lakes, among other examples. The activity concentration results of these radionuclides in rainfall, when combined with meteorological information, help to understand how aerosol particles are transported in the air and removed from the atmosphere by the action of rainfall. The objectives of this work were to determine the activity concentrations of the natural radionuclides 7Be and 210Pb in rainfall samples over a period of two years, from January 2021 to December 2022, in each rainy event that occurred on the IPEN campus, located in the city of São Paulo, Brazil. Be-7 activity concentrations were measured by non-destructive gamma-ray spectrometry using a coaxial Be-layer HPGe detector with 25% relative efficiency and associated electronic devices and live counting time varying from 80,000 s to 300,000 s; 210Pb activity concentrations were measured by gross beta counting in a low background gas flow proportional detector, after radiochemistry procedure. The annual rainfall indices for 2021 and 2022 were 1093 mm and 1391 mm, respectively. Activity concentrations for 7Be ranged from 0.459 ± 0.038 Bq L-1 to 8.96 ± 0.57 Bq L-1 and for 210Pb from 0.015 ± 0.001 to 0.98 ± 0.01 Bq L-1 in the studied period. The results obtained of 7Be and 210Pb in rainfall were correlated to seasons, precipitation, temperature, and sunspot number for 7Be. The higher values obtained for the concentrations were in winter and spring time presenting good correlations with the amount of precipitation and sunspot number and a clear seasonal variation.
CASTRO, J.O.; DOMINGOS, R.M.; DAMATTO, S.R.; RODRIGUES, C.E.C.; ISIKI, V.L.; NETO, J.O.A.
Two years of continuous monitoring of 7Be and 210Pb in rainfall collected at the IPEN campus, São Paulo, Brazil.
In:
INTERNATIONAL CONFERENCE ON ENVIRONMENTAL RADIOACTIVITY, 7th,
September 17-22, 2023,
Seville, Spain.
Abstract...
Seville, Spain: Universidad de Sevilla,
2023.
p. 311-311.
Disponível em: http://repositorio.ipen.br/handle/123456789/34455. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
AYLLON, R.M.
; TORRECILLA, J.K.
; SAUEIA, C.R.
; NISTI, M.B.
; EL HAJJ, T.M.; FURLAN, M.R.; SILVA, P.S.C.
.
Activity concentration of natural radionuclides (238U, 226Ra, 232Th, 228Ra, 210Pb and 40K) in soil amended with niobium tailings.
In: INTERNATIONAL CONFERENCE ON ENVIRONMENTAL RADIOACTIVITY, 7th,
September 17-22, 2023,
Seville, Spain.
Abstract...
Seville, Spain: Universidad de Sevilla,
2023.
p. 217-217.
Abstract:
The storage of tailing from anthropic activities like mining, which may contain radionuclide traces, is a problematic situation consequent from NORM industries activities and for which they seek alternatives. The study presented in this paper is related to carbonate deriving from niobium extraction. This carbonate is stored in dams, which can cause an increase in radionuclides and metals concentration, imposing restrictions on its use. To ensure the safe usage of the residue, it is assessed the activity concentration of 238U, 226Ra, 232Th, 228Ra, 210Pb and 40K in soil samples as well as mixture soil + carbonate, soil + carbonate + lime, soil + lime and soil. The techniques used were gamma spectrometry and instrumental neutron activation analysis. Activity concentration evaluation was performed before and after the tillage of lettuce (Lactuca sativa) and bean (Phaseolus vulgaris), and the soil-plant transfer factor was determined for lettuce. The study of radionuclides and metals availability in the soil solution is important for a better understanding of the mobility of contaminants in water/soil systems, in order to estimate the real environmental impact. Preliminary results show samples with niobium traces presented values within the recommended world values.
AYLLON, R.M.; TORRECILLA, J.K.; SAUEIA, C.R.; NISTI, M.B.; EL HAJJ, T.M.; FURLAN, M.R.; SILVA, P.S.C.
Activity concentration of natural radionuclides (238U, 226Ra, 232Th, 228Ra, 210Pb and 40K) in soil amended with niobium tailings.
In:
INTERNATIONAL CONFERENCE ON ENVIRONMENTAL RADIOACTIVITY, 7th,
September 17-22, 2023,
Seville, Spain.
Abstract...
Seville, Spain: Universidad de Sevilla,
2023.
p. 217-217.
Disponível em: http://repositorio.ipen.br/handle/123456789/34454. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ROSSI, WAGNER de
; WETTER, NIKLAUS U.
; DIPOLD, JESSICA
; BORDON, CAMILA D.S.; KASSAB, LUCIANA R.P..
Waveguide amplifiers produced by femtosecond laser in doped heavy metal glasses.
In: EUROPEAN SUMMIT ON LASER OPTICS & PHOTONICS TECHNOLOGY,
September 25-27, 2023,
Barcelona, Spain.
Abstract...
2023.
Abstract:
Waveguides are very suitable structures for integrating optics in miniaturized systems such as those involved in microfluidics. With them, it is possible to stimulate reactions using light and collect information from optical signals from specific points of a given system. Thus, for example, it is possible to transport light from an external source to a microreactor within a microfluidic system and/or collect the emission of any reagent or reaction from any point in the system. In this context, several kinds of research have been carried out for the development of waveguides in transparent materials suitable for use in microfluidic systems such as lab-on-a-chip. A widely used way of producing such guides is through the focusing of ultrashort laser pulses (fs) inside transparent materials. In this case, the intensity is adjusted so that the absorbed energy is sufficient to change the crystalline arrangement in the focal region, but not enough to cause catastrophic damage, that is, that there is no rupture of bonds between atoms. This change in the local arrangement of atoms (or ions) leads to a localized change in the index of refraction, which can be used to refract light. If a line of such regions, or points, has an index of refraction greater than that of the surrounding medium, then it is possible to guide light within it as in an optical fiber. If the index of refraction changes to a value less than that of the neighboring medium, then it is only possible to guide the light between two or more of these lines.
This work describes the development and characterization of waveguides produced with two lines by processing heavy metal oxide glasses with a femtosecond laser. Tellurite (TeO2-ZnO) and germanate (GeO2-PbO) glasses were used [1,2], pure and also doped with rare earth. Raman spectroscopy shows a decrease in the photoinduced refractive index, from -7.4x10-3 to 1x10-5, depending on the material and processing conditions. Thus, it is not possible to guide light inside a single line and, therefore, two of these lines were used for this purpose, with the guidance being done between them. The work details the laser machining process, the physical and spatial characteristics of the guides produced, the characteristics of the guided spatial mode, such as the M2 parameter, the transmission losses, and the gain obtained when glasses doped with rare earths are used.
ROSSI, WAGNER de; WETTER, NIKLAUS U.; DIPOLD, JESSICA; BORDON, CAMILA D.S.; KASSAB, LUCIANA R.P.
Waveguide amplifiers produced by femtosecond laser in doped heavy metal glasses.
In:
EUROPEAN SUMMIT ON LASER OPTICS & PHOTONICS TECHNOLOGY,
September 25-27, 2023,
Barcelona, Spain.
Abstract...
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34453. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GATTI, LUCIANA
; CUNHA, CAMILLA; MARANI, LUCIANO; CASSOL, HENRIQUE; MESSIAS, CASSIANO; ARAI, EGIDIO; SOLER, LUCIANA; ALMEIDA, CLAUDIO; SETZER, ALBERTO; DOMINGUES, LUCAS
; DENNING, SCOTT; MILLER, JOHN; GLOOR, MANUEL; CORREIA, CAIO; CRISPIM, STEPHANE; CORREA, SERGIO; NEVES, RAIANE; SILVA, FRANCINE; MACHADO, GUILHERME.
Direct measurements can help to understand the changes in ecosystems: Amazonia a case study.
In: EGU GENERAL ASSEMBLY,
April 23-28, 2023,
Vienna, Austria.
Abstract...
Göttingen, Germany: Copernicus,
2023.
Abstract:
The Amazon is the largest rainforest on the planet and was an important carbon sink. The carbon
sink is declining, mainly due to an increase in tree mortality as a result of deforestation,
degradation, and local, regional and global climate change. In addition, deforestation and forest
degradation reduce the ability of the Amazon rainforest to act as a carbon sink. CO2 Vertical
Profiles (VP) were performed from 2010 to 2021 (805), using small aircraft at 4 locations: SAN
(2.86° S 54.95° W), ALF (8.80° S 56.75° W), RBA (9.38° S 67.62° W) and from 2010 to 2012 on TAB
(5.96° S 70.06° W) and since 2013 at TEF (3.39° S 65.55° W). The question if Amazonia is a carbon
source or sink is an important role in the global carbon budget. Amazonia vertical profile annual
mean derived from CO2 annual mean vertical profiles (VP subtracted from the background
concentration: ΔVP) from the 4 studied sites can help to clarify this important question. The
sampling frequency was approximately 2 times per month in each location, from 4.4 km height
(a.s.l.) until near surface 300 m (a.s.l.), and usually carried out between 12:00 and 13:00 local time.
The CO2 samples were analyzed at INPE's LaGEE (Greenhouse Gas Laboratory), in São Jose dos
Campos. This result is a direct indication of the regional source in the global carbon budget,
indeed there are well-known discrepancies from many studies using different methodologies
(bottom-up, top-down techniques, and a wide variety of global, regional, and inversion models). In
this study, we will present Carbon flux from the time series for the 4 sites and Amazon Carbon
balance using the column budget technique, and analyze the correlations with various parameters
related to climate, vegetation, deforestation, and biomass burning.
GATTI, LUCIANA; CUNHA, CAMILLA; MARANI, LUCIANO; CASSOL, HENRIQUE; MESSIAS, CASSIANO; ARAI, EGIDIO; SOLER, LUCIANA; ALMEIDA, CLAUDIO; SETZER, ALBERTO; DOMINGUES, LUCAS; DENNING, SCOTT; MILLER, JOHN; GLOOR, MANUEL; CORREIA, CAIO; CRISPIM, STEPHANE; CORREA, SERGIO; NEVES, RAIANE; SILVA, FRANCINE; MACHADO, GUILHERME.
Direct measurements can help to understand the changes in ecosystems: Amazonia a case study.
In:
EGU GENERAL ASSEMBLY,
April 23-28, 2023,
Vienna, Austria.
Abstract...
Göttingen, Germany: Copernicus,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34452. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GARCIA, PRISCILA
; ORTIZ, NILCE
.
Fotodecomposição solar para remoção de BTEX em água subterrânea contaminada pela atividade de posto de gasolina.
In: CONGRESSO INTERNACIONAL DE MEIO AMBIENTE SUBTERRÂNEO, 7th,
August 30-31, 2023,
São Paulo, SP.
Abstract...
São Paulo, SP: Associação Brasileira de Águas Subterrâneas - ABAS,
2023.
p. 1-2.
GARCIA, PRISCILA; ORTIZ, NILCE.
Fotodecomposição solar para remoção de BTEX em água subterrânea contaminada pela atividade de posto de gasolina.
In:
CONGRESSO INTERNACIONAL DE MEIO AMBIENTE SUBTERRÂNEO, 7th,
August 30-31, 2023,
São Paulo, SP.
Abstract...
São Paulo, SP: Associação Brasileira de Águas Subterrâneas - ABAS,
2023.
p. 1-2.
Disponível em: http://repositorio.ipen.br/handle/123456789/34447. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SANTOS, JOEL M. dos
; MATSUDA, MARGARETH M.N.
; ARAUJO, ELAINE B. de
.
Validação de método para determinação de estanho total por ICP-OES em reagente liofilizado TIN-TEC.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
OBJETIVOS – O fluoreto estanoso, princípio ativo do reagente liofilizado TIN-TEC, também atua como agente redutor do Tecnécio-99m (99mTc) que é o radioisótopo mais utilizado na medicina nuclear para obtenção de imagens para diagnóstico por SPECT de várias enfermidades. O 99mTc apresenta propriedades físicas ideais e pode variar oestado de oxidação de -1 a +7, quando reage com uma variedade de compostos orgânicos e inorgânicos na presença de Sn+2. Entretanto, Sn+2 é instável e pode ser oxidado a Sn+4 na presença de oxigênio e em soluções aquosas pode precipitar como um fluoreto básico insolúvel. A utilização de método analítico não descrito em compêndio oficial reconhecido pela ANVISA requer a realização de uma validação analítica. O objetivo deste trabalho foi validar o método utilizado na quantificação de estanho total em amostra de reagente liofilizado TIN-TEC, usando espectroscopia de emissão óptica com plasma indutivamente acoplado (ICP-OES) como método alternativo inovador, uma vez que a técnica está sendo introduzida para a análise de estanho, em substituição ao método espectrofotométrico no visível com ditiol, descrito na farmacopeia europeia.
MATERIAIS E MÉTODOS – As análises foram realizadas em um ICP-OES Vista MPX Agilent equipado com nebulizador de vidro Seaspray, utilizando argônio como plasma e gás auxiliar. As amostras foram introduzidas direta e sequencialmente no plasma, com o auxílio da bomba peristáltica, utilizando-se as linhas de emissão 189,927 e 242,950 nm. A metodologia foi validada contemplando os ensaios de seletividade, linearidade/faixa de trabalho, repetibilidade, precisão intermediária e robustez. A concentração de Sn foi relacionada à quantidade de fluoreto estanoso e o limite de aceitação foi estabelecido entre 90-110 % para a quantidade presente na formulação do RL.
RESULTADOS – A curva de calibração apresentou-se linear na faixa de 1,52 a 2,27 µg mL–1, obtendo-se coeficiente de correlação da curva de calibração de 0,995, superior a 0,99 que é o requisito de aceitação para linearidade de métodos analíticos. Todos os outros ensaios obedeceram aos critérios de aceitação com valores de massa de estanho compreendidas entre 90-110 % e com desvios padrão relativo (DPR)< 5%.
CONCLUSÕES – O método analítico proposto para determinação de Sn total no reagente liofilizado TIN-TEC por ICP-OES foi validado e os resultados mostraram que a técnica ICP-OES apresenta vantagens sobre o método espectrofotométrico para estanho descrito na Farmacopeia Europeia como método limite.
SANTOS, JOEL M. dos; MATSUDA, MARGARETH M.N.; ARAUJO, ELAINE B. de.
Validação de método para determinação de estanho total por ICP-OES em reagente liofilizado TIN-TEC.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34443. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SANTOS, PRISCILA L.C.
; BERNARDES, EMERSON S.
.
Guideline para gerenciamento de resíduos em radiofarmácia hospitalar com sistema gerador de 68Ge/68Ga.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
O gerador de 68Ge/68Ga é um sistema portátil de produção do radionuclídeo Gálio-68 utilizado no preparo de radiofármacos para medicina nuclear com tecnologia PET. Ganhou popularidade nos últimos anos devido ao potencial promissor para diversas aplicações diagnósticas, como diagnóstico de tumores neuroendócrinos (DOTATOC-68Ga) e câncer de próstata (PSMA-68Ga). A importância e o número de serviços licenciados para uso desta tecnologia vêm aumentando, mas existem poucos documentos técnicos que orientem sobre o gerenciamento de resíduos provenientes desse sistema em radiofarmácia hospitalar.
O presente trabalho teve como objetivo promover o uso seguro do sistema gerador de 68Ge/68Ga através da criação de um guideline que aborda o gerenciamento de resíduos desde a classificação, segregação, acondicionamento, disposição final e tratamento de todos os tipos de resíduos em radiofarmácia hospitalar.
Para elaboração deste guideline foi realizada uma revisão da literatura em revistas científicas disponíveis em plataformas on-line e legislações da área. Para definição do formato e conteúdo do guideline foram consultados 15 documentos em formato de guia destinados às instalações radiativa e nucleares tendo como autoria órgãos, agências e revistas científicas internacionais. A partir dessas referências, foi estabelecido que cada guideline deveria conter os seguintes elementos: título, data, autores, escopo, sumário, introdução, conteúdo específico, conflito de interesse e referências bibliográficas.
Este guideline apresentou os resíduos que podem ser gerados na rotina de uma radiofarmácia hospitalar com sistema gerador de 68Ge/68Ga. Além dos rejeitos radioativos, os resíduos podem ser infectantes, químicos, radioativos, comuns e perfuro cortante e, na maioria das vezes, se enquadram em mais de um grupo ao mesmo tempo. Diante disso, é essencial que o programa de gerenciamento contemple ações desde a etapa de geração, segregação, armazenamento temporário e definitivo dos resíduos.
Para os rejeitos radioativos, o radionuclídeo Gálio-68 que se enquadra na classe 1, rejeito de meia-vida muito curta (67,71 minutos) e o Germânio-68 que pertence à classe 2, com meia-vida longa (270,95 dias) e, portanto, mais crítico.
A partir de um cenário fictício, demonstrou-se que o tempo de armazenamento de rejeitos líquidos gerados em 12 meses de operação podem chegar a 8,4 anos devido ao Germânio-68. A segregação em sólidos e líquidos é de extrema importância pois reduz significativamente o volume (38%) e o tempo total de armazenamento.
Uma vez disponibilizado à comunidade científica, este manual contribuirá para a disseminação de conhecimento, capacitação de profissionais e para condução eficiente e segura dos resíduos minimizando os riscos relativos à saúde humana, animal, meio ambiente e aos recursos naturais renováveis.
SANTOS, PRISCILA L.C.; BERNARDES, EMERSON S.
Guideline para gerenciamento de resíduos em radiofarmácia hospitalar com sistema gerador de 68Ge/68Ga.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34442. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SANTOS, JOEL M. dos
; ARAUJO, ELAINE B. de
; DOMINGO, MARIA; BALIEIRO, LUIZA M.
; FREIRE, MARIA R.V.B.
; SILVA, LUANA P. da
.
Estudo de avaliação de estabilidade do peptídeo PSMA I&T com lutécio-177 para transporte e aplicão clínica.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
Objetivo: O objetivo deste trabalho foi estudar a estabilidade de dose terapêutica de PSMA-I&T radiomarcado com lutécio-177, acondicionada sob congelamento e após descongelamento, simulando condição de transporte e utilização clínica do produto. A formulação é composta por tampão ascorbato de sódio (tampão de marcação), em concentração otimizada, sem estabilizantes adicionais. Materiais e Métodos: Foram realizadas marcações de PSMA-I&T com cerca de 9,25 GBq de cloreto de lutécio-177, fornecidos por dois produtores, com atividade específica em torno de 22Ci/mg 740GBq/mg. As marcações foram feitas em meio tamponado pH 4,7 (tampão ascorbato de sódio), a 90°C por 30 minutos, a pureza radioquímica (PR) foi determinada por cromatografia em camada delgada (CCD) e cromatografia líquida de alta eficiência (CLAE), e a dose terapêutica, com volume final entre 1,0 e 2,0 mL, foi armazenada sob congelamento por até 7 dias para avaliação da estabilidade em intervalos de tempo pré-estabelecidos. Ao final do maior período de armazenamento, a dose terapêutica foi completamente descongelada e armazenada em câmara climática a 30°C e 35% de umidade para simular condição de uso e avaliar a estabilidade por CCD e CLAE. Resultados: A %PR das doses terapêuticas avaliadas por CCD manteve-se elevada (> 98%) quando armazenadas sob congelamento por 48 horas, período suficiente para promover o transporte para diferentes regiões do país e garantindo a aplicação clínica. Mesmo após 7 dias sob congelamento a %PR manteve-se elevada e após descongelamento, a %PR manteve-se praticamente inalterada. Vale ressaltar que este sistema cromatográfico é útil apenas para determinar a porcentagem de lutécio-177 livre. Na análise por CLAE foi possível identificar outras impurezas radioquímicas, em pequena porcentagem. A %PR, por CLAE, das amostras armazenadas sob congelamento por 48 horas também apresentou valores de %PR acima do especificado (> 95%). Após 7 dias de armazenamento sob congelamento, seguido do armazenamento na câmara climática com a amostra mantida em condições controladas sob 30°C e 35% de umidade, foi observado um aumento no número de picos no CLAE (outras impurezas radioquímicas) gerados, provavelmente, por efeito da radiólise, afetando diretamente a %PR com valores entre 92 a 94%. Conclusões: Os resultados mostram que a marcação do peptídeo (PSMA I&T) com 177Lu, para diferentes fornecedores, em tampão ascorbato pH 4,7, sem adição de conservantes adicionais, mantém-se estável por 48 horas, quando mantido sob congelamento, com valor de %PR acima de 97% determinado pelas técnicas de CCD e CLAE. Este estudo encontra-se em desenvolvimento e serão avaliadas outras marcações para certificação da estabilidade de produção deste radiofármaco.
SANTOS, JOEL M. dos; ARAUJO, ELAINE B. de; DOMINGO, MARIA; BALIEIRO, LUIZA M.; FREIRE, MARIA R.V.B.; SILVA, LUANA P. da.
Estudo de avaliação de estabilidade do peptídeo PSMA I&T com lutécio-177 para transporte e aplicão clínica.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34441. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
RAED, M.D.; BONIFACIO, D.A.B.
; MEJIA, J.; MORAES, E.R..
Primeira imagem tomográfica para a proposta de protótipo de micro-PET brasileiro.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
Objetivo:
Este trabalho visa, a partir da Eletrônica de detecção PETSYS TOFPET2, propor um protótipo de sistema de aquisição capaz de obter imagens tomográficas, bem como, formar mão de obra para atuar no desenvolvimento de um tomógrafo por emissão de pósitrons Brasileiro.
Materiais e Métodos:
Para a aquisição e digitalização do sinal foi utilizada a eletrônica de detecção PETSYS TOFPET2 Evaluation Kit, juntamente com cristais de LYSO segmentados, os quais estavam acoplados a fotomultiplicadoras de silício (SiPM). A fonte de radiação utilizada foi uma fonte de 22Na, de atividade de 1 MBq a qual foi colocada no centro do campo de visão. Para se obter diversos ângulos de resposta efetuou-se a rotação da fonte. As reconstruções tomográficas foram realizadas a partir do algoritmo OSEM (ordered subset expectation-maximization), sem correções, implementado no próprio grupo de pesquisa. A simulação do sistema, para comparação, foi realizada com a ferramenta de código aberto GATE ( Geant4 Application for Emission Tomography).
Resultados:
Os dados adquiridos pelo sistema PETSYS, bem como as simulações, foram processados de modo a obter-se a posição global dos eventos em relação ao centro de rotação do sistema. A partir destas foram encontradas as linhas de resposta utilizadas na montagem dos sinogramas. As imagens reconstruídas do sistema físico foram então comparadas com as simuladas, sendo observada concordância entre ambas.
Conclusão:
O sistema em desenvolvimento mostrou-se capaz de adquirir e montar os sinogramas, bem como reconstruir as imagens tomográficas. Foi visto que as imagens reconstruídas de uma aquisição com fonte rotante, apresentaram-se concordantes com as imagens obtidas da simulação do sistema. Os resultados apresentados são apenas preliminares, sendo necessários estudos mais aprofundados da resposta do sistema, bem como, implementação de correções nas imagens, de modo aumentar a qualidade delas.
RAED, M.D.; BONIFACIO, D.A.B.; MEJIA, J.; MORAES, E.R.
Primeira imagem tomográfica para a proposta de protótipo de micro-PET brasileiro.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34440. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
POZZO, LORENA
; OLIVEIRA, MERCIA L. de
.
A utilização do PET/CT no Sistema Único de Saúde (SUS): o cenário atual após 9 anos de incorporação.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
Introdução. A incorporação de tecnologias de alta complexidade como o PET/CT deve ser constantemente analisada e aprimorada para que ocorra favorecendo sua consolidação. A avaliação quanto ao desempenho desses equipamentos contribui no entendimento da efetividade clínica, da utilização desses dispositivos na vida real do paciente e do impacto dessa tecnologia nas diferentes regiões em que estão inseridas. Objetivos. Deste modo, buscou-se avaliar a distribuição geográfica de equipamentos e procedimentos de PET/CT em uso no SUS e seus aspectos econômicos. Metodologia. Busca ativa de informações a partir de levantamentos bibliográficos e consultas em sites que apresentassem dados de interesse (ANVISA, DATASUS, CNEN, entre outros). Resultados. Identificou-se treze registros sanitários de equipamentos de sete fabricantes distintos dentro do período de vigência. Há 110 inscrições junto ao CNES de estabelecimentos com pelo menos um equipamento PET/CT e 160 matrículas de instalações autorizadas pela CNEN. O valor sugerido para tais equipamentos em 2022, divulgado pelo FNS é R$ 6.405.000,00. Os impostos observados são: IPI, PIS e COFINS. O valor pago pela tabela SUS é R$ 2.107,22 por procedimento e o valor total pago desde a incorporação, R$ 348.446.738,37. Conclusão. Poucos são os estados que com PET/CT por 1,5 milhão de habitantes para atender a demanda prevista e evitar áreas de vazios assistenciais. A complexidade da área eleva o custo de implementação e de manutenção de serviços de PET/CT, o que dificulta a expansão de sua oferta de maneira equânime em todo o território nacional.
POZZO, LORENA; OLIVEIRA, MERCIA L. de.
A utilização do PET/CT no Sistema Único de Saúde (SUS): o cenário atual após 9 anos de incorporação.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34439. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, VINICIUS L.T. de
; SANTOS, LUAN J. dos
; ROCHA, CLAUDIO J. da
; FELGUEIRAS, CARLOS F.
; OTUBO, LARISSA
; MATSUDA, MARGARETH M.N.
.
Estudo preliminar de validação de filtração esterilizante: microscopia em filtros de GUAN-IPEN-123.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
OBJETIVO - O processo de filtração esterilizante deve ser validado para comprovar que a esterilização do produto é efetiva nas condições reais de processo e que o filtro não causa alterações prejudiciais na composição do produto e que o produto não altera a eficiência do filtro. Quando um produto não pode ser esterilizado no recipiente final, as soluções devem ser filtradas através de um filtro estéril de tamanho de poro nominal de 0,22 micrômetros ou menor. Na validação da filtração esterilizante devem ser realizados os seguintes testes: compatibilidade entre o filtro e o produto, verificação da adsorção de componentes do produto e substâncias extraíveis, e o desafio microbiológico com 1x107 unidades formadoras de colônia (UFC) de Brevundimonas diminuta por cm2 de superfície do filtro. A filtração esterilizante é o método de escolha para esterilização de radiofármacos como é ocaso de GUAN-IPEN-123 iobenguano (123 I). O objetivo deste trabalho é realizar estudo preliminar por microscopia eletrônica de varredura do filtro esterilizante após filtração do radiofármaco GUAN-IPEN-123 e do microrganismo Pseudomonas aeruginosa. MATÉRIAIS E MÉTODOS – Utilizou-se microscópio eletrônico de varredura (SEM-FEG) marca Jeol modeloJSM-6701F, membrana de filtração Millipore Millex-GV (fluoreto de polivinilideno) 0,22 μm, microrganismo BioMerieux Bioball Pseudomonas aeruginosa NCTC 12924. Foram obtidas microscopias da membrana, após filtração de GUAN-IPEN-123 e após passagem de 5 mL de Pseudomonas aeruginosa de cerca de 4,5x108 UFC. Os filtros foram submetidos a decaimento do I-123 e as membranas foram secas e o microrganismo foi fixado com etanol PA para obtenção das microscopias após recobrimento com carbono. RESULTADOS – A microscopia da membrana antes da filtração de GUAN-IPEN-123 mostrou integridade da superfície e a dimensão do poro conforme, sendo adequado para uso em filtração esterilizante. Após a filtração, foi observada deposição de material sobre a membrana. A presença de Pseudomonas aeruginosa (tamanho entre 0,5 μm a 0,8 μm) sobre a superfície da membrana indicou retenção do microrganismo de tamanho similar a Brevundimonas diminuta utilizada na validação de filtração esterilizante. CONCLUSÃO – As microscopias por SEM-FEG e a utilização do microrganismo Pseudomonas aeruginosa mostraram-se adequadas na análise preliminar das membranas utilizadas na filtração esterilizante do radiofármaco GUAN-IPEN-123.
OLIVEIRA, VINICIUS L.T. de; SANTOS, LUAN J. dos; ROCHA, CLAUDIO J. da; FELGUEIRAS, CARLOS F.; OTUBO, LARISSA; MATSUDA, MARGARETH M.N.
Estudo preliminar de validação de filtração esterilizante: microscopia em filtros de GUAN-IPEN-123.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34436. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OKAWABATA, FRANCINE S.
; OLIVEIRA, NATHALIE C.; YAMAGA, LILIAN Y.I.; BARBOSA, ANNA C.A.; SATO, KAREN A.K.; NOGUEIRA, SOLANGE A.; VITOR, TAISE; RODRIGUES JUNIOR, ORLANDO
.
Manual de boas práticas para procedimentos de radioembolização com 90Y.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
Objetivo: O objetivo geral deste trabalho é apresentar um manual de boas práticas para os procedimentos de radioembolização com 90Y também conhecido como a Radioterapia Interna Seletiva (SIRT), com foco na proteção radiológica, destinado principalmente aos profissionais envolvidos na manipulação, aquisição das imagens e assistência aos pacientes, visto que das 80 instalações de Medicina Nuclear com autorização para o uso de 90Y, apenas 14 possuem cadastro no Fabricante das microesferas. A elaboração do manual destinado a todos os profissionais da saúde envolvidos no procedimento visa capacitar e treinar para a execução das etapas necessárias, de modo a garantir o melhor resultado para o paciente. Metodologia: Para realizar a radioembolização com 90Y é imprescindível compreender e executar algumas etapas. A compreensão dessas etapas é crucial para garantir que as microesferas de 90Y sejam manipuladas de acordo com as boas práticas, permitindo que o tratamento seja realizado com segurança e efetividade. O primeiro passo é a calibração do ativímetro, também conhecido como calibrador de doses, para o radioisótopo 90Y, encontrando o fator de calibração. É importante considerar que a atividade contida no frasco de transporte possui uma variação de+/- 10% e requer atenção em relação ao fuso horário. O próximo passo será a manipulação, para essa etapa foi confeccionada uma proteção de acrílico de 15 mm. A eficiência da proteção será avaliada realizando de 10medições utilizando um detector de radiação Geiger-Muller. A mesma avaliação será realizada para o protetor de seringa de acrílico. Resultados: Os resultados da taxa de exposição com a utilização das blindagens de acrílico demonstram uma eficiência de 96,5% na redução da taxa de dose e de 95,2% ao utilizar o protetor de seringa, comprovando a eficácia da proteção; medida de segurança indispensável durante o processo de manipulação. Com isso, visando garantir a adequada implementação dessas melhorias e a execução correta em cada etapa do processo, foi elaborado um Procedimento Operacional Padrão e todas as informações foram compiladas em um manual de boas práticas. Conclusão: A elaboração do Manual de Boas Práticas na forma de um Procedimento Operacional Padrão é fundamental para padronizar e orientar as etapas do processo, assegurando uma proteção radiológica efetiva. Este documento também poderá ser utilizado por serviços que desejam iniciar a realização da Radioembolização e no treinamento de novas equipes em serviços já estabelecidos.
OKAWABATA, FRANCINE S.; OLIVEIRA, NATHALIE C.; YAMAGA, LILIAN Y.I.; BARBOSA, ANNA C.A.; SATO, KAREN A.K.; NOGUEIRA, SOLANGE A.; VITOR, TAISE; RODRIGUES JUNIOR, ORLANDO.
Manual de boas práticas para procedimentos de radioembolização com 90Y.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34435. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
NARIO, ARIAN P.
; SANTOS, SOFIA N. dos
; ROSSI, WAGNER de
; BERNARDES, EMERSON S.
.
Síntese, caracterização in vitro e in vivo de um novo traçador PET como potencial agente para hipóxia tumoral.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
Introdução. Hipóxia é uma condição patológica caracterizada pela redução no fornecimento de oxigênio para um determinado tecido ou célula. Atualmente sabe-se que a hipóxia no microambiente tumoral está intimamente relacionada a: 1) aumento da agressividade tumoral; 2) aumento na taxa de recidivas; 3) aumento de resistência à quimioterapia e 4)radioterapia e pior prognóstico. Em comparação com outros métodos de diagnóstico por imagem não invasivos, a Tomografia por Emissão de Pósitrons (PET) é uma das modalidades mais utilizadas na detecção de hipóxia tumoral devido a sua maior especificidade e resolução espacial. Objetivos. Os objetivos do trabalho foram: 1) sintetizar e caracterizar um radiofármaco inédito marcado com 18F, [18F]N-(4-fluorobenzil)-2-(2-nitro-1h-imidazol-1-il)acetamida [18F]FBNA, para a detecção de áreas de hipóxia no microambiente tumoral através de imagem molecular PET e comparar esse produto inédito com o radiofármaco [18F]FAZA utilizado hoje em dia em estudos clínicos para detecção de hipóxia tumoral. Materiais e Métodos. A molécula FBNA foi sintetizada e caracterizada química e estruturalmente por técnicas espectroscópicas. A preparação do [18F]FBNA foi otimizada em relação à quantidade de precursor, temperatura e tempo de reação. Estudos de estabilidade em solução salina, soro fisiologico, coeficiente de partição e uma comparação in vitro e in vivo com o 18F-FAZA foi feita. Resultados. O FBNA foi obtido com alta pureza química e radioquímica (> 90%), o rendimento radioquímico foi de 67 ± 13%, a atividade específica foi 2,5 ± 0,8% GBq/μmol e o tempo total da síntese foi aproximadamente 180 minutos. O novo radiofármaco mostrou-se estável em salina e em soro por até 6 horas e mais lipofílico que o [18F]FAZA. Estudos de captação celular in vitro em duas linhagens tumorais de câncer gástrico humano, demonstraram que o [18F]FBNA é captado especificamente por células em hipóxia e não em células em condições normóxicas com melhores resultados em comparação ao 18F-FAZA. Com a imagem μPET, autorradiografia, e os estudos de biodistribuição ex vivo, verificou-se que o [18F]FBNA foi captado mais rápido e apresentou valores das relações Tumor/Músculo e Tumor/Sangue mais favoráveis em comparação com o[18F]FAZA, o que sugere uma eliminação mais rápida, menor captação por órgãos inespecíficos e maior qualidade de imagem do que o [18F]FAZA. Conclusão. O composto inédito do presente trabalho apresentou resultados pré-clínicos superiores ao padrão [18F]FAZA utilizado em ensaios clínicos hoje em dia, pelo que podemos concluir de nossos resultados preliminares que o radiofármaco [18F]FBNA apresenta condições favoráveis para ser o próximo radiotraçador para o diagnóstico de hipóxia na prática clínica.
NARIO, ARIAN P.; SANTOS, SOFIA N. dos; ROSSI, WAGNER de; BERNARDES, EMERSON S.
Síntese, caracterização in vitro e in vivo de um novo traçador PET como potencial agente para hipóxia tumoral.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34434. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MARTINS, ELAINE W.
; POTIENS, MARIA da P.A.
.
Aplicação de calibração de ativímetro para 131I.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
Introdução
: Em setores de medicina nuclear (SMN) os materiais radioativos são amplamente utilizados, tanto para diagnóstico quanto para terapias, e suas atividades devem ser determinadas com precisão antes da administração a um paciente obtendo resultados desejáveis do tratamento. Para garantir a confiabilidade da dose prescrita pelo médico é utilizado o instrumento de medição nomeado de ativímetro, anteriormente chamado de curiômetro. A Comissão Nacional de Energia Nuclear estabelece que nos SMN tenha pelo menos um ativímetro e que sejam realizados testes periódicos de um programa de controle de qualidade. Esses medidores de atividade devem ser bem calibrados para que forneça resultados os mais confiáveis possíveis e os fatores de calibração devem ser rastreáveis para cada radionuclídeo. Em SMN os ativímetros comumente estão localizados em áreas controladas, de difícil acesso e encontram dificuldade para transportá-lo corroborando para um impasse em sua calibração. Pensando nisso o Laboratório de Calibração de Instrumentos pertencente ao Instituto de Pesquisas Nucleares (IPEN) vem desenvolvendo metodologias de calibração “in situ” onde é transportado apenas o radionuclídeo e não o ativímetro. Objetivo
: Implementação da metodologia de calibração "in situ" desenvolvida que permite sua execução apenas com o deslocamento das amostras radioativas e não do próprio ativímetro. Materiais e Métodos:
Neste trabalho foram testados onze ativímetros pertencentes ao setor de produção de radiofármacos do IPEN utilizando o radionuclídeo
131
I usado para tratamento tanto para distúrbios não malignos quanto para câncer de tireoide. Fatores de calibração foram determinados para cada ativímetro. Resultados e Conclusões
: Após a aplicação da metodologia por técnicos qualificados, os resultados obtidos dos ativímetros testados mostraram sua importância visto que os fatores de calibração podem apresentar correção de até 5% para
131
I.
MARTINS, ELAINE W.; POTIENS, MARIA da P.A.
Aplicação de calibração de ativímetro para 131I.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34433. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GOMES, ANTONIO A.
; NARIO, ARIAN P.
; LAPOLLI, ANDRE L.
; LANDULFO, EDUARDO
; BERNARDES, EMERSON S.
; ROSSI, WAGNER de
.
Microfluídica, uma tecnologia aplicada à concentração de 18F para produção de radiofármacos.
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
Introdução. O uso de radiofármacos marcados com 18F para o diagnóstico clínico por imagem PET (tomografia por emissão de pósitrons) de diversas doenças tem aumentado consideravelmente. O maior radiofármaco aplicado a diagnósticos com PET é o [18F]-2-desoxi-2-fluoro-D-glicose (FDG) e a sua preparação requer a utilização de equipamentos especializados (e caros) para proteger o farmacêutico que o prepara. Assim, à medida que a demanda de radiofármacos PET aumentar, colocará uma pressão significativa nas instalações de produção de traçadores PET, a qual necessitará de investimento em novas tecnologias de produção de radiofármacos. Uma tecnologia chave desenvolvida nos últimos tempos tem sido o uso de sistemas microfluídicos. Os dispositivos microfluídicos oferecem muitas vantagens para a síntese de radiofármacos de curta duração (por exemplo, 18F)tais como: reações mais rápidas, transferência de calor eficiente, alta relação superfície – volume e rendimentos mais elevados. Embora os sistemas microfluídicos estudados para radiofármacos existam há quase 20 anos, no Brasil, até onde sabemos, esta tecnologia e estudo é inédita. Objetivos. Apresentar os primeiros resultados no desenvolvimento de um chip microfluídico para uma “microcoluna” destinada ao processo de retenção e eluição de 18F. Metodologia. A microcoluna foi usinada em vidro óptico de borosilicato – BK7 utilizando a técnica de ablação com laser de pulsos ultracurtos. Após a microusinagem, a microcoluna é preenchida com a mesma resina utilizada no cartucho convencional de síntese “Sep-Pak Accell Plus QMA Plus Light” da fabricante Waters™. Ambas são posteriormente submetidas a testes de desempenho comparativos de eficiência na fase de retenção e eluição de 18F. Resultados. Foram realizados 4 testes comparativos para ambas as fases (primeira etapa da síntese de 18F-FDG), com atividades (1,5 ± 0,3 mCi e 248 ± 11 mCi; “n = 2”). Os resultados demostraram que a eficiência da microcoluna é equivalente à da coluna convencional (QMA Plus Light) na fase de retenção (99,3% ± 0,67 vs99,6% ± 0,32). No entanto, na fase de eluição de 18F, houve uma diferença significativa entre ambas (99,93% ±0,18 vs 77,38% ± 15,54), destacando a grande vantagem da microcoluna. Conclusão. A integração do cartucho de troca iônica em um chip, com a técnica de ablação com laser de pulso ultracurto, abre as portas para chips de radiofarmácia menores e mais eficientes para a produção de 18F-FDG e outros compostos. Os resultados experimentais inéditos no Brasil demonstram que as etapas iniciais da produção de doses prontas para humanos (pré-concentração de flúor) podem ser realizadas com uma eficiência superior nos parâmetros de eluição do 18Fem comparação a síntese com cartucho convencional.
GOMES, ANTONIO A.; NARIO, ARIAN P.; LAPOLLI, ANDRE L.; LANDULFO, EDUARDO; BERNARDES, EMERSON S.; ROSSI, WAGNER de.
Microfluídica, uma tecnologia aplicada à concentração de 18F para produção de radiofármacos.
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34432. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FERNANDES, JAQUELINE C.
; ARAUJO, ELAINE B. de
; JOAQUIM, ADRIANA I..
Incidência de eventos adversos relacionados a terapias com o radiofármaco iodeto de sódio (131I).
In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Abstract:
Objetivos:
Radiofármacos com finalidade terapêutica vêm sendo cada vez mais utilizados para tratamento de diversas patologias. Os radionuclídeos emissores beta destacam-se nessa modalidade devido às características físicas da partícula emitida. O iodo-131 (
131
I) é um exemplo de radionuclídeo emissor beta, aplicado na produção de radiofármacos como o iodeto de sódio (131I) que representa uma excelente modalidade terapêutica no tratamento de carcinomas diferenciados da tireoide. Assim como as demais modalidades empregadas na terapia do câncer, a terapia radionuclídica utilizando-se radiofármacos também pode provocar reações adversas. Esse estudo teve como objetivo avaliar a incidência de possíveis eventos adversos relacionados à terapia com o radiofármaco iodeto de sódio (131I), bem como correlacionar os mesmos com as atividades administradas, obtendo dados inéditos de farmacovigilância relacionado ao uso de radiofármacos terapêuticos no Brasil.
Metodologia:
Foi realizada uma análise retrospectiva de prontuários eletrônicos de pacientes diagnosticados com carcinoma diferenciado da tireoide e submetidos à radioiodoterapia.
Resultados:
Foram recuperados 116 pacientes no período de Janeiro/2019 a abril/2021 e 89 foram incluídos de acordo com os critérios de inclusão. Dos pacientes recuperados, 47 (54,6 %) relataram algum evento adverso após a radioiodoterapia. Os eventos mais frequentes foram aqueles relacionados ao trato gastrointestinal e irradiação local e foi possível identificar que há um aumento da incidência de eventos naqueles pacientes que foram tratados com atividades maiores.
Conclusões:
Com base nos resultados obtidos, o presente estudo demonstrou a presença de eventos agudos relacionados à terapia na população estudada, e que a incidência dos eventos apresenta correlação com o a atividade prescrita.
FERNANDES, JAQUELINE C.; ARAUJO, ELAINE B. de; JOAQUIM, ADRIANA I.
Incidência de eventos adversos relacionados a terapias com o radiofármaco iodeto de sódio (131I).
In:
CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 37.,
21-23 de setembro, 2023,
Porto de Galinhas, PE.
Resumo...
São Paulo, SP: Sociedade Brasileira de Medicina Nuclear - SBMN,
2023.
Disponível em: http://repositorio.ipen.br/handle/123456789/34431. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
UFALA, I.D.
; SANTOS, L.C.
; POTIENS, M.P.A.
.
Avaliação do desempenho de uma câmara monitora em feixes de referência para radiodiagnóstico.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 132-132.
Abstract:
Introdução: O Laboratório de Calibração de Instrumentos, LCI, do IPEN possui
arranjos e sistemas de irradiação para a realização a calibração de instrumentos
medidores de radiação. Para a utilização de feixes de radiação X, estes arranjos possuem
uma câmara de ionização monitora, cuja função é permitir a correção de um resultado
de uma medição qualquer pela sua medição. Isto ocorre porque elas são fixas e cobrem
todo o feixe de radiação. Elas não precisam, necessariamente, de calibração, porém é
necessário conhecer muito bem suas características e seu desempenho. O objetivo deste
trabalho é analisar o desempenho da câmara de ionização de transmissão utilizada no
LCI para os feixes de radiação recomendados para radiodiagnóstico. Materiais e Métodos: O sistema de calibração do LCI utilizado é composto por um
equipamento de radiação X, um sistema de medição de referência com certificado de
calibração do PTB e uma câmara de ionização de transmissão PTW. Os feixes de
radiação testados foram os recomendados pela norma IEC 61267 para feixes diretos
(RQR) e atenuados (RQA). A tensão aplicada ao tubo variou de 50 a 150 kV com
corrente de 10 mA em todos os casos e as medições foram realizadas em carga (nC). Resultados e Discussões: Os resultados obtidos com a câmara monitora em
comparação com os feixes de referência estão apresentados na Tabela 1. Conclusões: Os resultados obtidos com a câmara monitora demonstra sua adequação
para ser utilizada como um padrão de trabalho nas calibrações a serem realizadas.
UFALA, I.D.; SANTOS, L.C.; POTIENS, M.P.A.
Avaliação do desempenho de uma câmara monitora em feixes de referência para radiodiagnóstico.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 132-132.
Disponível em: http://repositorio.ipen.br/handle/123456789/34429. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TEODORO, L.
; TALACIMON, C.
; MEDEIROS, I.
; RIGO, M.
; GESSERAME, M.
; RODRIGUES, P.
; NOGUEIRA, T.
; ROSERO, W.
; VIEIRA, J.
; ZEITUNI, C.
; ROSTELATO, M.
.
Produção de fonte polimérica de fósforo-32 para braquiterapia.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 208-208.
Abstract:
Introdução: O câncer do Sistema Nervoso Central (SNC) é o 18º câncer mais incidente
do mundo, de acordo com a Organização Mundial da Saúde, e em 2020, no Brasil,
representou 2,5% de todas as novas mortes por câncer. Uma fonte radioativa promissora
para uso em braquiterapia para tratamento de câncer no SNC é o fósforo-32 em um
substrato polimérico. Faz-se necessária uma produção brasileira desta fonte. Materiais e Métodos: Como o fósforo-32 apresenta-se em formato líquido (ácido
ortofosfórico, H3
32PO4), para produzir uma fonte polimérica que o contenha é necessário
verificar quais resinas conseguem incorporá-lo. Assim, testou-se diversos tipos de
resina, desde látex industrial até borrachas de silicone, misturando-as à mesma
quantidade de ácido (sem radioatividade a princípio) para verificar a curabilidade de
cada resina. Em todos os testes, as resinas curaram em moldes de 5 x 5 cm. Resultados e Discussões: O melhor candidato para a produção de placas poliméricas de
fósforo-32 é a borracha de silicone. Mesmo com a incorporação do ácido na resina, sua
maleabilidade não foi alterada e suas propriedades físicas foram mantidas. Conclusões: É possível haver uma produção brasileira de fontes poliméricas de
fósforo-32 brasileiras para tratamento de câncer no SNC.
TEODORO, L.; TALACIMON, C.; MEDEIROS, I.; RIGO, M.; GESSERAME, M.; RODRIGUES, P.; NOGUEIRA, T.; ROSERO, W.; VIEIRA, J.; ZEITUNI, C.; ROSTELATO, M.
Produção de fonte polimérica de fósforo-32 para braquiterapia.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 208-208.
Disponível em: http://repositorio.ipen.br/handle/123456789/34428. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TAVARES, P.V.
; PEREIRA, J.J.
; RODRIGUES JUNIOR, O.
; YORIYAZ, H.
; RODRIGUES, L.L.
.
Estudo de simulações Monte Carlo de curvas de PDP para diferentes energias de fótons com MCNP em um frasco de solução Fricke.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 113-113.
Abstract:
Introdução: O uso de fótons de diferentes energias na radioterapia é fundamental para ajustar a
dose de radiação de acordo com a profundidade do tumor e minimizar os efeitos colaterais em
tecidos saudáveis próximos. Fótons de baixa energia depositam a maior parte de sua energia
perto da superfície do corpo, enquanto fótons de alta energia podem penetrar mais
profundamente. A solução Fricke gel é um material ideal para uso como phantom, pois possui
densidade próxima à da água e permite a dosimetria a partir do aumento da concentração de Fe3+
causada pela irradiação. Além disso, essa solução pode ser utilizada para dosimetria na área de
radioterapia. O software MCNP é amplamente utilizado na simulação de transporte de radiação.
Neste trabalho, será realizado um estudo da dependência energética da solução Fricke a partir da
ferramenta MCNP ao simular diferentes energias de fótons. Materiais e Métodos: O MCNP foi utilizado na sua versão 6.2, simulando uma fonte em
formato de disco com raio de 5,0 cm, com espectros continuos de 6 MeV, 11 MeV, 15 MeV e
valores discretos de 1,17 MeV e 1,33 MeV para o 60Co, emitindo radiação de forma
monodirecional a uma distância de 100 cm do frasco. O frasco, por sua vez, consistia de um
cilindro de PET com 7 cm de comprimento, 2,5 cm de raio e 0,05 cm de espessura, preenchido
com solução de Fricke gel. Os resultados foram obtidos por meio do tally *F8, usado para
calcular a deposição de energia em MeV em cada um dos 69 pontos dentro do frasco. Resultados e Discussões: A curva de PDP resultado da simulação em fótons de diferentes energias mostra um
deslocamento da região de build up. O deslocamento ocorre por a interações eletromagnéticas
dos fótons em energias mais altas ocorrerem em uma maior profundidade no material. Conclusões: Conclui-se que esse deslocamento da região de build up na solução Fricke pode
ser de interesse com o objetivo de aumentar a profundidade da dose máxima. Essas simulações
poderão ser repetidas e comparadas com a ferramenta TOPAS e experimentos clínicos.
TAVARES, P.V.; PEREIRA, J.J.; RODRIGUES JUNIOR, O.; YORIYAZ, H.; RODRIGUES, L.L.
Estudo de simulações Monte Carlo de curvas de PDP para diferentes energias de fótons com MCNP em um frasco de solução Fricke.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 113-113.
Disponível em: http://repositorio.ipen.br/handle/123456789/34427. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TALACIMON, C.
; MEDEIROS, I.
; RODRIGUES, P.
; TEODORO, L.
; RIGO, M.
; GESSERAME, M.
; TAVARES, P.
; BURIN, A.
; NOGUEIRA, T.
; ROSERO, W.
; ZEITUNI, C.
; ROSTELATO, M.
.
Avaliação da estabilidade da solução de Fricke xilenol gel ao longo do tempo em diferentes condições de armazenamento.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 89-89.
Abstract:
Introdução: O Fricke Xilenol Gel (FXG) é um dosímetro químico considerado tecido
equivalente. A resposta do FXG se dá pela oxidação radio-induzida de Fe+2 em Fe+3.
Porém esta oxidação pode ocorrer naturalmente por diversos fatores como temperatura e
exposição à luz, e por isso faz necessário avaliar tal comportamento ao longo dos dias em
diversas condições. Materiais e Métodos: Amostras de FXG foram preparadas utilizando o protocolo
estabelecido previamente e foram divididas em duas partes. Em uma das partes foi
adicionado formaldeído como dopante. Ambas as partes foram divididas em quantidades
iguais e mantidas em diferentes temperaturas. A análise das amostras foi realizada através
de dados de absorbância coletados com um espectrofotômetro ao longo de vários dias. Resultados e Discussões: Foram observadas diferenças na oxidação natural entre as
amostras mantidas em refrigeração e aquelas mantidas em temperatura ambiente.
Também foram observadas diferenças entre as amostras com e sem formaldeído . Conclusões: As amostras mantidas em refrigeração apresentaram uma oxidação natural
muito inferior àquelas mantidas em temperatura ambiente.
TALACIMON, C.; MEDEIROS, I.; RODRIGUES, P.; TEODORO, L.; RIGO, M.; GESSERAME, M.; TAVARES, P.; BURIN, A.; NOGUEIRA, T.; ROSERO, W.; ZEITUNI, C.; ROSTELATO, M.
Avaliação da estabilidade da solução de Fricke xilenol gel ao longo do tempo em diferentes condições de armazenamento.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 89-89.
Disponível em: http://repositorio.ipen.br/handle/123456789/34426. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SOUZA, C.H.
; GRANJA, A.A.C.
; ANTUNES, P.C.G.
; SHORTO, J.M.B.
; YORIYAZ, H.
.
Análise da fluência de fótons de um feixe direto para construção de um modelo de fonte virtual de um acelerador linear clínico em Monte Carlo.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 169-169.
Abstract:
Introdução: Utilizando o espaço de fase (phsp) de um acelerador CyberKnife IRIS 60 mm,
este trabalho analisa as características do espectro de fótons do feixe direto (não espalhado)
no eixo central do equipamento, visando reconstruir a distribuição de fótons de
bremsstrahlung, originados no alvo espesso de tungstênio do equipamento, para modelagem
de uma fonte virtual de um linac utilizando simulações de Monte Carlo. Materiais e Métodos: A partir do código MCNP6, estimou-se a distribuição da fluência de
fótons originados: 1) pelo phsp da IAEA; 2) por um modelo composto de um feixe
monoenergético de elétrons incidindo sobre um alvo espesso de tungstênio, com e sem a
presença de um filtro de chumbo. A fluência foi estimada no ar, sob um SSD de 80 cm, pelo
uso de um voxel na forma de um cilindro de 2 cm de raio e 0.2 cm de altura. Resultados e Discussões: Pela Figura 1,
nota-se a possibilidade de reproduzir o
espectro de fótons do feixe direto de um
linac, a partir de um feixe elétrons incidindo
sobre um alvo espesso de tungstênio, com
boa aproximação. Vale ressaltar que o
modelo não leva em consideração os fótons
gerados pela interação da radiação com os
demais componentes do cabeçote do linac, o
que poderia gerar algum nível de divergência
na fluência de fótons de baixas energias. Conclusões: A partir do modelo apresentado, conclui-se que a utilização do espectro gerado
no feixe direto de um linac sem filtro aplainador pode ser uma boa aproximação para
modelagem computacional em Monte Carlo de uma fonte de radiação virtual de um linac com
phsp disponível.
SOUZA, C.H.; GRANJA, A.A.C.; ANTUNES, P.C.G.; SHORTO, J.M.B.; YORIYAZ, H.
Análise da fluência de fótons de um feixe direto para construção de um modelo de fonte virtual de um acelerador linear clínico em Monte Carlo.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 169-169.
Disponível em: http://repositorio.ipen.br/handle/123456789/34425. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
RODRIGUES, P.
; TALACIMON, C.
; MEDEIROS, I.
; TEODORO, L.
; RIGO, M.
; GESSERAME, M.
; TAVARES, P.
; NOGUEIRA, T.
; ROSERO, W.
; ZEITUNI, C.
; ROSTELATO, M.
.
Desenvolvimento de dosímetro Fricke xilenol gel para longo tempo de exposição.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 107-107.
Abstract:
Introdução: Os dosímetros Fricke xilenol gel (FXG) têm vantagens como a química bem
conhecida da solução e a equivalência do tecido em faixa de energias de fótons. O
objetivo deste trabalho é a produção do dosímetro FXG com adição de formaldeído para
utilização de irradiação de longo tempo. Materiais e Métodos: A receita FXG foi adaptada de Del Lama (2013) com adição de
0,189 M de formaldeído. Uma fonte de 60Co (Gammacell) foi utilizada para irradiação.
Para analisar o espectro visível, utilizou-se um espectrofotômetro Shimadzu UV-1800
nos comprimentos de ondas entre 350 e 650 nm. Resultados e Discussões: Os FXGs apresentaram duas bandas (Figura 1): em 439 e 578
nm correspondentes aos íons Fe2+ e Fe3+ originados pela radio-oxidação dos íons Fe2+. Conclusões: A produção de FXG modificada foi bem estabelecida e apresentou
vantagens como melhor difusão dos íons Fe2+ e estabilidade em relação ao FXG padrão.
RODRIGUES, P.; TALACIMON, C.; MEDEIROS, I.; TEODORO, L.; RIGO, M.; GESSERAME, M.; TAVARES, P.; NOGUEIRA, T.; ROSERO, W.; ZEITUNI, C.; ROSTELATO, M.
Desenvolvimento de dosímetro Fricke xilenol gel para longo tempo de exposição.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 107-107.
Disponível em: http://repositorio.ipen.br/handle/123456789/34424. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
RIGO, M.
; RODRIGUES, P.
; TALACIMON, C.
; TEODORO, L.
; NOGUEIRA, T.
; ROSERO, W.
; MEDEIROS, I.
; ZEITUNI, C.
; ROSTELATO, M.
.
Síntese de nanopartículas de ouro para aplicações em radioterapia.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 49-49.
Abstract:
Introdução: O rápido avanço da nanotecnologia nos últimos anos tem alimentado o
interesse crescente no campo da pesquisa de nanopartículas, particularmente sua
aplicação na terapêutica e no diagnóstico do câncer. Sendo assim, busca-se o emprego de
nanopartículas como instrumento para a braquiterapia. Materiais e Métodos: A partir de adaptações do método de Turkevich (1951) obteve se
ácido cloroáurico (HAuCl4) um componente importante para a síntese de nanopartículas
de ouro (AuNPs). As nanopartículas foram funcionalizadas com polietilenoglicol 5000
(NH2-PEG-SH). Resultados e Discussões: Avaliou-se a quantidade de citrato correlacionado com o
tamanho das AuNPs e consequentemente à coloração da solução. Também verificou se a
estabilidade das nanopartículas. Para estas reações examinou-se o tamanho das partículas
por DLS. Conclusões: Os resultados obtidos foram satisfatórios quanto ao tamanho e a
estabilidade, mostrando que o uso e aplicações em nanobraquiterapia é favorável.
RIGO, M.; RODRIGUES, P.; TALACIMON, C.; TEODORO, L.; NOGUEIRA, T.; ROSERO, W.; MEDEIROS, I.; ZEITUNI, C.; ROSTELATO, M.
Síntese de nanopartículas de ouro para aplicações em radioterapia.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 49-49.
Disponível em: http://repositorio.ipen.br/handle/123456789/34423. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
RAED, M.D.; BONIFACIO, D.A.B.
; MORAES, E.R..
Desenvolvimento de um modelo simples de tomografo por emissão de pósitrons utilizando a eletrônica PETSYS TOFPET2.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 65-65.
Abstract:
Introdução: A tomografia por emissão de pósitrons é utilizada em diversas áreas, como
estudos de novos fármacos, e pesquisas translacionais e imagem molecular. Nesse âmbito,
este trabalho visa a partir da Eletrônica de detecção PETSYS TOFPET2 elaborar um
protótipo de sistema de tomografia por emissão de pósitrons, para utilização em estudos
pré-clínicos envolvendo pequenos animais. Materiais e Métodos: Utilizamos a eletrônica de detecção PETSYS TOFPET2 para a
montagem de um arranjo experimental composto por dois cristais segmentados, no qual
uma fonte de 22Na localizada no centro do sistema, pode ser rotacionada de modo a obter
distintos ângulos de aquisição permitindo a obtenção da imagem. Resultados e Discussões: Os distintos ângulos coletados foram organizados e
processados de modo obter os sinogramas, utilizados para a reconstrução tomográfica. Conclusões: O sistema em desenvolvimento mostrou-se capaz de adquirir e montar os
sinogramas para aquisições com fonte rotante, entretanto, os resultados apresentados são
apenas preliminares, sendo necessários estudos mais aprofundados da resposta do sistema
de modo a obter imagens de melhor qualidade.
RAED, M.D.; BONIFACIO, D.A.B.; MORAES, E.R.
Desenvolvimento de um modelo simples de tomografo por emissão de pósitrons utilizando a eletrônica PETSYS TOFPET2.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 65-65.
Disponível em: http://repositorio.ipen.br/handle/123456789/34422. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PERES, B.
; TAVARES, P.V.
; RODRIGUES JUNIOR, O.
; CAMPOS, L.L.
.
Avaliação do emprego de solução Fricke gel e gel polimérico na dosimetria em radioterapia empregando a técnica de CT óptico.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 95-95.
Abstract:
Introdução: O planejamento de radioterapia exige avaliação precisa da dose em diferentes
tecidos. O gel polimérico é uma opção que, ao ser irradiada, sofre polimerização proporcional à
dose depositada. Embora o gel polimérico apresenta melhor estabilidade da informação
dosimétrica do que a solução Fricke gel, sua produção e padronização são mais complexas. No
entanto, soluções de polímeros orgânicos adicionadas à solução Fricke podem ter respostas a
doses mais altas e serem facilmente descartadas. Este trabalho avalia a solução Fricke gel
modificada com alaranjado de xilenol e a utilização de CT óptico. A proposta é avaliar a
dosimetria 3D das soluções em gel para a preparação de uma solução Fricke polimérica. Materiais e Métodos: A solução Fricke gel foi preparada nas concentrações propostas por
Tavares,2021 e avaliada antes e após a irradiação com radiação gama do 60Co, utilizando para a
avaliação, o CT Óptico Vista 16, que emprega uma fonte de luz de comprimento de onda de
590nm. Resultados e Discussões: O valor da atenuação para a solução não irradiada é 0,0555 cm-1 e o valor de atenuação para a
solução irradiada com 5 Gy é 0,22 cm-1. O que o equipamento avaliou foi a alteração da
densidade óptica, proporcional à dose recebida pela solução. Conclusões: A dosimetria a partir dos géis apresenta vantagens para o uso na radioterapia, já
que o método de avaliação por CT óptico consegue identificar as alterações, em regiões,
relacionadas à irradiações, permitindo a construção de curvas de isodose. Este resultado poderá
ser comparado com a preparação de um gel Fricke polimérico observando a polimerização da
solução que altera as propriedades ópticas.
PERES, B.; TAVARES, P.V.; RODRIGUES JUNIOR, O.; CAMPOS, L.L.
Avaliação do emprego de solução Fricke gel e gel polimérico na dosimetria em radioterapia empregando a técnica de CT óptico.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 95-95.
Disponível em: http://repositorio.ipen.br/handle/123456789/34421. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PEREIRA, J.J.
; TAVARES, P.V.
; YORIYAZ, H.
; RODRIGUES JUNIOR, O.
; CAMPOS, L.L.
.
Desempenho comparativo do código MCNP na simulação de diferentes tamanhos de feixes de irradiação de fótons de 6 MeV em solução Fricke para Física Médica.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 182-182.
Abstract:
Introdução: A escolha do tamanho do feixe de radioterapia depende do volume alvo do
tratamento. Feixes menores são utilizados com o objetivo de reduzir a dose em tecidos saudáveis
circundantes. A solução Fricke gel é um material ideal para uso como phantom e dosimetria em
radioterapia devido à sua densidade próxima à da água e capacidade de aumento da concentração
de Fe3+ com irradiação. O MCNP é um código amplamente utilizado para simulação de transporte
de radiação e será utilizado em um estudo comparativo em simulações de diferentes tamanhos de
feixes de irradiação de fótons de 6 MeV em solução Fricke. O objetivo é avaliar sua eficiência e
precisão para essa aplicação. Materiais e Métodos: Este estudo utilizou simulações de Monte Carlo com o código mencionado
anteriormente, na versão 6.2, para modelar uma fonte em formato de disco com raios de 0,5 cm,
1,5 cm, 2,5 cm e 5,0 cm, apresentando um espectro contínuo de 6 MeV e direção única, localizada
a 100 cm de distância do alvo. O alvo consistiu em um cilindro de PET com 7 cm de comprimento,
2,5 cm de raio e 0,05 cm de espessura, preenchido com solução Fricke gel. A grandeza de interesse
foi avaliada por meio do tally *F8, que mediu a deposição de energia em MeV em cada um dos
69 pontos no interior do alvo. Resultados e Discussões: A curva de perfil de dose por profundidade da solução Fricke simulada mostra uma
proximidade entre as regiões de build up das simulações. Isto representa que as regiões de
interações dos fótons com a solução não variaram. Conclusões: O resultado apresenta uma proximidade na região de build up que é de interesse com
o objetivo de manter a dose máxima na distância do volume alvo preservando volumes adjacentes.
Para validação e comparação, as simulações poderão ser repetidas com a ferramenta de Monte
Carlo TOPAS.
PEREIRA, J.J.; TAVARES, P.V.; YORIYAZ, H.; RODRIGUES JUNIOR, O.; CAMPOS, L.L.
Desempenho comparativo do código MCNP na simulação de diferentes tamanhos de feixes de irradiação de fótons de 6 MeV em solução Fricke para Física Médica.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 182-182.
Disponível em: http://repositorio.ipen.br/handle/123456789/34420. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
NASCIMENTO, G.
; RODRIGUES, O.
; POTIENS, M.P.A.
.
Desafios na introdução da física radiológica em cursos de nível técnico de radiologia.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 32-32.
Abstract:
Introdução: Com o aumento constante na busca por uma profissão nos últimos anos, as
instituições de ensino começaram a aumentar a diversidade do seu corpo discente. Entre
os diversos cursos visados, quando focamos na área da saúde a radiologia é um dos cursos
mais procurados. Entretanto, estudos apontam que grande parte dos ingressantes no curso
buscam somente um bom salário com uma jornada de trabalho reduzida. Com interesse
em desmistificar o conhecimento em física dos alunos de um curso técnico em radiologia,
questionários foram elaborados e preenchidos pelos discentes, com intuito de conhecer
os alunos e a realidade do conhecimento em física radiológica nas instituições abordadas. Materiais e Métodos: As informações foram organizadas utilizando a plataforma de
formulários do google (google forms), 10 questões alternativas foram elaboradas, sendo
perguntas de apresentação pessoal e de conhecimentos específicos. Cada uma das 08 salas
abordadas foi apresentada à ideia do projeto. A pesquisa foi realizada no curso técnico de
radiologia em 03 unidades de uma instituição de ensino no nível técnico. Resultados e Discussões: Os resultados mostram que, segundo os alunos, o principal
motivo pela escolha do curso técnico em radiologia foi a presença de contatos ou parentes
dentro da área (52%), seguido pela jornada de trabalho reduzida (31%). Somente 21(9%)
dos 230 alunos participantes afirmam ter escolhido o curso por ter curiosidades dentro da
área. Conclusões: Pode-se concluir que, pela falta de interesse ou tempo hábil para se dedicar
aos estudos, os alunos acabam apresentando dificuldade em disciplinas que podem ser
mais complexas e requerem mais atenção. Parentes ou contatos dentro da área também
apresentam ser um dos fatores preocupantes na dedicação aos estudos, já que os alunos
tendem relaxar dentro desse ambiente propicio a um acesso a facilitado ao mercado de
trabalho.
NASCIMENTO, G.; RODRIGUES, O.; POTIENS, M.P.A.
Desafios na introdução da física radiológica em cursos de nível técnico de radiologia.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 32-32.
Disponível em: http://repositorio.ipen.br/handle/123456789/34419. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
NASCIMENTO, G.
; CAMPOS, V.P.
; CAMPOS, L.L.
.
Caracterização da reprodutibilidade de detectores de LiF:Mg, Ti utilizando dosímetros termoluminescentes de extremidade no modelo anel do IPEN no rod phantom com irradiações na grandeza Hp(0,07).
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 99-99.
Abstract:
Introdução: A radiologia, em especial a radiologia intervencionista e a medicina nuclear,
são as duas principais áreas de exposição do indivíduo ocupacionalmente exposto (IOE),
sendo necessário a utilização de dosímetros. Para que um dosímetro possa ser utilizado
com certa confiabilidade, é necessário que ele passe por alguns testes de calibração e
caracterização. Neste trabalho, o ensaio de reprodutibilidade é realizado seguindo as
recomendações do Comitê de Avaliação de Serviços de Ensaio e Calibração (CASEC). Materiais e Métodos: As equações utilizadas nesta sessão são recomendadas pela
apostila do CASEC, para dosimetria de corpo inteiro, porém, neste trabalho, adaptadas
para dosimetria de extremidade. O rod phantom utilizado neste trabalho pertence ao
Laboratório de Calibração de Instrumentos do IPEN (LCI-IPEN). Para as irradiações, foi
utilizado um sistema Irradiador Pantak/Seifeirt modelo Isovolt 60 Hs na faixa do
radiodiagnóstico. As qualidades N-60, N-80, N-100 e N-150 foram avaliadas neste
trabalho. Resultados e Discussões: A média das 10 avaliações da resposta TL apresentou uma
baixa variação de resultados para as irradiações de 10 mSv na grandeza Hp(0,07)
utilizando 118 keV. Para o ensaio de reprodutibilidade para uma mesma dose, a média
das 10 avaliações para uma dose de 10 mSv na grandeza Hp(0,07) com uma energia de
118 keV, apresentou baixa variação da resposta. Conclusões: Os sistemas dosimétricos e sistemas irradiadores apresentaram uma boa
reprodutibilidade, tanto em dose avaliada quanto no resultado após a interação com a
equação. As irradiações na grandeza Hp(0,07) foram bem sucedidas, confirmando a
importância da utilização de um phantom em situações de caracterização e calibração.
NASCIMENTO, G.; CAMPOS, V.P.; CAMPOS, L.L.
Caracterização da reprodutibilidade de detectores de LiF:Mg, Ti utilizando dosímetros termoluminescentes de extremidade no modelo anel do IPEN no rod phantom com irradiações na grandeza Hp(0,07).
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 99-99.
Disponível em: http://repositorio.ipen.br/handle/123456789/34418. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MEDEIROS, I.
; TALACIMON, C.
; TEODORO, L.
; RIGO, M.
; RODRIGUES, P.
; CORREIA, R.
; ROSERO, W.
; ROSTELATO, M.
; ZEITUNI, C.
.
Cálculo da contaminação de iodo-126 na produção do iodo-125.
In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 43-43.
Abstract:
Introdução: O interesse no radionuclídeo iodo-125 baseia-se em sua variabilidade em
aplicações médicas, dentre elas a braquiterapia. Ele pode ser gerado em reator nuclear,
porém neste processo forma-se também o iodo-126, subproduto indesejável. Este trabalho
tem como objetivo avaliar a contaminação do iodo-126 no iodo-125 gerado no reator
IEA-R1 do IPEN, para ser utilizado em sementes para tratamento de câncer. Materiais e Métodos: Para obter o iodo-125, irradiou-se cápsulas contendo o gás
xenônio-124 no reator IEA-R1. Recuperou-se o gás de interesse por meio de uma solução
de hidróxido de sódio (NaOH). As amostras foram analisadas por um detector de
germânio hiperpuro (HPGe) para verificar a proporção de iodo-125 e iodo-126 gerados.
Nota-se que o iodo-126 gera gamas de 388,6 keV e 668,3 keV que atrapalha o uso do
iodo-125 em aplicações médicas. Resultados e Discussões: O iodo-125 produzido apresentou pureza radionuclídica maior
que 99%. É necessário que a quantidade de iodo-126 seja no máximo de 0,9%. Conclusões: A produção no reator IEA-R1, as cápsulas de irradiação adotadas e o sistema
de detecção se mostraram adequados. A validação deste processo mostra que o IPEN
possui autonomia para produzir iodo-125 e utilizá-lo em aplicações da medicina nuclear.
MEDEIROS, I.; TALACIMON, C.; TEODORO, L.; RIGO, M.; RODRIGUES, P.; CORREIA, R.; ROSERO, W.; ROSTELATO, M.; ZEITUNI, C.
Cálculo da contaminação de iodo-126 na produção do iodo-125.
In:
CONGRESSO BRASILEIRO DE FISICA MEDICA, 27.,
12-15 de junho, 2023,
São Pedro, SP.
Resumo...
São Paulo, SP: Associação Brasileira de Física Médica - ABFM,
2023.
p. 43-43.
Disponível em: http://repositorio.ipen.br/handle/123456789/34417. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
View more
Buscar no repositório
Navegar
-
Todo o repositório
-
Esta coleção
Minha conta
Refinar
Estatísticas
Visualizar
A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.
✔ É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do
Buscar no Repositório
, isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.
✔ A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em
Navegar
✔ Os filtros disponíveis em
Navegar
tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro,
Autores IPEN
apresenta uma relação com os autores vinculados ao IPEN; o
ID Autor IPEN
diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome;
Tipo de acesso
diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.
A opção
Busca avançada
utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.
Exemplo:
Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.
Autor: Maprelian
Título: loss of coolant
Tipo de publicação: Texto completo de evento
Ano de publicação: 2015
✔ Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da
International Atomic Energy Agency – IAEA
, por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.
✔ 95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN,
[email protected]
.
✔ Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.
✔ O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.
✔ Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.
✔ Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).
ATENÇÃO!
ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI,
clique aqui.
2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI,
clique aqui.
O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.
Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.